Validation of a Second-Generation Near-Infrared Spectroscopy Monitor in Children With Congenital Heart Disease

Abstract: This study calibrated and validated the FORE-SIGHT Elite tissue oximeter to accurately measure SctO2 in pediatric patients with the medium sensor.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 37 publications
0
11
0
Order By: Relevance
“…The former includes venous blood from extracerebral tissue and may overestimate the actual cerebral venous saturation 24 , 45 . However, validation studies of NIRS devices predominantly use human jugular bulb oxygen saturation measurements 46 48 . We did not directly measure brain tissue oxygen tension; the oxygen dissociation curve is likely to be shifted at the tissue level by the acidotic brain pH and other local factors.…”
Section: Discussionmentioning
confidence: 99%
“…The former includes venous blood from extracerebral tissue and may overestimate the actual cerebral venous saturation 24 , 45 . However, validation studies of NIRS devices predominantly use human jugular bulb oxygen saturation measurements 46 48 . We did not directly measure brain tissue oxygen tension; the oxygen dissociation curve is likely to be shifted at the tissue level by the acidotic brain pH and other local factors.…”
Section: Discussionmentioning
confidence: 99%
“…Near‐infrared spectroscopy (NIRS) for measurement of regional cerebral oxygenation was used to detect a possible decrease in cerebral perfusion. In a recent clinical study, an acceptable agreement with a weighted average from arterial und jugular bulb oxygenation saturation could be demonstrated 23 …”
Section: Discussionmentioning
confidence: 90%
“…Previous studies have identified Deming regression analysis as a valid method to analyze the agreement between clinical monitoring methods, and it can be used to assess whether there is a fixed or proportional bias between the two monitoring methods ( Haji et al, 2015 ; Nasr et al, 2019 ). In this study, the Deming regression analysis was y = 5.6387 + 0.9067 x ( y is BIS, s is Ai), and the slope and intercept were both statistically significant.…”
Section: Discussionmentioning
confidence: 99%