2015
DOI: 10.5194/amt-8-2509-2015
|View full text |Cite
|
Sign up to set email alerts
|

Validation of first chemistry mode retrieval results from the new limb-imaging FTS GLORIA with correlative MIPAS-STR observations

Abstract: Abstract. We report first chemistry mode retrieval results from the new airborne limb-imaging infrared FTS (Fourier transform spectrometer) GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) and comparisons with observations by the conventional airborne limb-scanning infrared FTS MIPAS-STR (Michelson Interferometer for Passive Atmospheric SoundingSTRatospheric aircraft). For GLORIA, the flights aboard the high-altitude research aircraft M55 Geophysica during the ESSenCe campaign (ESa Sound… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

6
0

Authors

Journals

citations
Cited by 14 publications
(18 citation statements)
references
References 29 publications
0
18
0
Order By: Relevance
“…Characteristics of MIPAS-STR, the data processing and uncertainties of the retrieval results are briefly summarized in the following. Further information on MIPAS-STR is found in Keim et al (2008), Woiwode et al (2015) and references therein. MIPAS-STR em-3360 E. Eckert et al: MIPAS IMK/IAA CFC-11 and CFC-12: accuracy, precision and long-term stability ploys four liquid He-cooled detectors/channels in the spectral range between 725 and 2100 cm −1 (13.8 and 4.8µm).…”
Section: Mipas-str Datamentioning
confidence: 99%
“…Characteristics of MIPAS-STR, the data processing and uncertainties of the retrieval results are briefly summarized in the following. Further information on MIPAS-STR is found in Keim et al (2008), Woiwode et al (2015) and references therein. MIPAS-STR em-3360 E. Eckert et al: MIPAS IMK/IAA CFC-11 and CFC-12: accuracy, precision and long-term stability ploys four liquid He-cooled detectors/channels in the spectral range between 725 and 2100 cm −1 (13.8 and 4.8µm).…”
Section: Mipas-str Datamentioning
confidence: 99%
“…During these campaigns, the instrument was constantly improved , the data processing was revised Guggenmoser et al, 2015), the level 2 products were validated Woiwode et al, 2015;Ungermann et al, 2015), and GLORIA data proved to be useful for model validation (Khosrawi et al, 2017) and case studies Krisch et al, 2017). Improvements to the instrument (reduced aero-acoustic noise in the spectra) compared to the results of Woiwode et al (2015) also increase the quality of the measured infrared spectra, resulting in different characteristics of the retrieved temperature and trace gas profiles.…”
Section: Gloriamentioning
confidence: 99%
“…Lower CI values indicate a larger influence of clouds on the spectrum. In previous studies using comparable airborne limb-emission observations, typically fixed cloud index thresholds between 2 and 4 were used Woiwode et al, 2012Woiwode et al, , 2015. In this work, a CI threshold of 3 is used for the lowest and 1.8 for the highest limb tangent altitude to account also for observations moderately affected by PSCs.…”
Section: Retrievalmentioning
confidence: 99%
See 2 more Smart Citations