2019
DOI: 10.1016/j.apradiso.2019.04.009
|View full text |Cite
|
Sign up to set email alerts
|

Validation of gamma scanning method for optimizing NaI(Tl) detector model in Monte Carlo simulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
3
0
3

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(6 citation statements)
references
References 29 publications
0
3
0
3
Order By: Relevance
“…NaI(Tl) detectors is one of the most used materials in gamma-ray spectrometry and the important features of these detectors are the energy spectrum response function and the efficiency curve, including full energy peak efficiency and total efficiency [1]. The accurate full energy peak efficiency (FEPE) calibration curve of NaI(Tl) detectors is required for most of the radioactive monitoring applications [2][3][4].…”
Section: Introductionmentioning
confidence: 99%
“…NaI(Tl) detectors is one of the most used materials in gamma-ray spectrometry and the important features of these detectors are the energy spectrum response function and the efficiency curve, including full energy peak efficiency and total efficiency [1]. The accurate full energy peak efficiency (FEPE) calibration curve of NaI(Tl) detectors is required for most of the radioactive monitoring applications [2][3][4].…”
Section: Introductionmentioning
confidence: 99%
“…Monte Carlo codes have been used for gamma scanning of distillation columns to optimize detector models by calculating their effi ciencies under different energies and at different distances [10], to design collimators and investigate their effect on the performance of the gamma scanning system [11], and to provide a visual representation of the process and anomalies inside the columns [12].…”
Section: Introductionmentioning
confidence: 99%
“…Deneysel kalibre işlemleri labaratuvarlarda bulunan standart gama kaynakları kullanılarak yapılmaktadır. Dedektör sisteminin gama sayım verimliliğini tüm gama enerjileri için deneysel olarak belirlemek sınırlı sayıda tek enerjili gama yayınlayan radyoizotopların olmasından dolayı neredeyse imkansızdır [1,11]. Ayrıca bu standart radyoaktif kaynaklar oldukça pahalı ve uzun süren laboratuvar çalışmaları gerektirir [11].…”
Section: Introductionunclassified
“…Dedektör sisteminin gama sayım verimliliğini tüm gama enerjileri için deneysel olarak belirlemek sınırlı sayıda tek enerjili gama yayınlayan radyoizotopların olmasından dolayı neredeyse imkansızdır [1,11]. Ayrıca bu standart radyoaktif kaynaklar oldukça pahalı ve uzun süren laboratuvar çalışmaları gerektirir [11]. Deneysel olarak tanımlanamayan ara enerjideki gama-ışınlarının verimliliğinin tanımlanması iki yolla mümkündür.…”
Section: Introductionunclassified