2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) 2009
DOI: 10.1109/nssmic.2009.5401776
|View full text |Cite
|
Sign up to set email alerts
|

Validation of GATE simulations of the <sup>176</sup>Lu intrinsic activity in LSO detectors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…Although the magnitude of the signal background resulting from natural 176 Lu in LSO-based scanners has been characterized [810], there is only one published study to our knowledge that examines the effect of 176 Lu background on measurements of weak sources in the field of view of a preclinical scanner [11]. We know of no previously published studies that have compared the performance of clinical scanners based upon the most common PET detector materials LSO and BGO in this low-activity range.…”
Section: Introductionmentioning
confidence: 99%
“…Although the magnitude of the signal background resulting from natural 176 Lu in LSO-based scanners has been characterized [810], there is only one published study to our knowledge that examines the effect of 176 Lu background on measurements of weak sources in the field of view of a preclinical scanner [11]. We know of no previously published studies that have compared the performance of clinical scanners based upon the most common PET detector materials LSO and BGO in this low-activity range.…”
Section: Introductionmentioning
confidence: 99%
“…This intrinsic activity within the LYSO crystals was simulated as a 176 Lu ion source, which is the most accurate method to simulate the radioactive decay 44 . The intrinsic activity source encompassed the whole scanner, and the activity (ion source) was confined to the LYSO scintillation crystals 53 . To quantify the impact of intrinsic activities, scanner performance was simulated with and without intrinsic activities.…”
Section: Methodsmentioning
confidence: 99%
“…44 The intrinsic activity source encompassed the whole scanner, and the activity (ion source) was confined to the LYSO scintillation crystals. 53 To quantify the impact of intrinsic activities, scanner performance was simulated with and without intrinsic activities. The count rate curves for DMI four-ring configuration with and without 176 Lu background intrinsic activities are generated for visual inspection, and the ratio of NECR with and without intrinsic activity is estimated.…”
Section: Intrinsic Activity In Lyso Crystalsmentioning
confidence: 99%