2014
DOI: 10.1080/15459624.2014.925114
|View full text |Cite
|
Sign up to set email alerts
|

Validation of Heart Rate Derived from a Physiological Status Monitor-Embedded Compression Shirt Against Criterion ECG

Abstract: Firefighters are subject to extreme environments and high physical demands when performing duty-related tasks. Recently, physiological status monitors (PSM) have been embedded into a compression shirt to enable firefighters to measure, visualize, log, and transmit vital metrics such as heart rate (HR) to aid in cardiovascular risk identification and mitigation, thereby attempting to improve the health, fitness, and safety of this population. The purpose of this study was to validate HR recorded by the PSM-embe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 20 publications
0
16
0
Order By: Relevance
“… Dolezal et al (2014). [ 28 ] Ten healthy men, age 21.0 ± 1.0 years, height 184 ± 5 cm and weight 91 ± 10 kg. 10 Criterion validity & agreement.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“… Dolezal et al (2014). [ 28 ] Ten healthy men, age 21.0 ± 1.0 years, height 184 ± 5 cm and weight 91 ± 10 kg. 10 Criterion validity & agreement.…”
Section: Resultsmentioning
confidence: 99%
“…[ 27 ] 5 Lead ECG Cycle ergometer Rest 1.00 ≥0.99 12- Stages 0.00 ≥0.99 Recovery 2.00 ≥0.99 Dolezal et al (2014). [ 28 ] 12 Lead ECG Treadmill Walk 0.04 0.99 Search (Crawl) − 0.01 0.99 Stairs −0.13 0.99 Fast walk 0.03 0.99 Smith et al (2014). [ 29 ] 3 Lead ECG Treadmill Walk −0.40 0.99 Search (Crawl) −1.70 0.95 Stairs 0.40 0.99 Gatti et al (2014).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Use of real-time physiologic monitors may extend beyond the fireground and aid in early identification of distress occurring hours after a high-stress incident. Unfortunately, research exploring use and utility of continuous physiologic monitoring is incomplete and information on cost limited [11, 12]. This creates a dilemma for fire department administrators and physician medical directors.…”
Section: Discussionmentioning
confidence: 99%
“…Devices may have built in alarms to warn the firefighter that they have reached some threshold value of physiology or may transmit data in real time to a monitoring station. Multiple studies have attempted to validate the devices within the context of fire suppression and it seems likely this trend in research of device application and functionality will continue [11, 12]. …”
Section: Introductionmentioning
confidence: 99%