2003
DOI: 10.1081/jlc-120021286
|View full text |Cite
|
Sign up to set email alerts
|

Validation of HPLC Analysis of Aspartate and Glutamate Neurotransmitters Following o ‐Phthaldialdehyde‐Mercaptoethanol Derivatization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2003
2003
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 16 publications
0
2
0
1
Order By: Relevance
“…[11][12][13] As a result, a highly sensitive analytical technique is required. To date, a variety of techniques have been utilized to analyze AA neurotransmitters in the microdialysate such as biosensors, [14] microchip electrophoresis, [15] CE-LIF, [16] LC-MS, [17] HPLC, [18,19] etc… Among these, HPLC is most common due to its advantages in operation, cost, and repeatability. Fluorescence detector (FLD) is most widely used in the HPLC detection of AA neurotransmitters, [20][21][22] but the electrochemical detector (ECD) is a better choice partly because of its sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…[11][12][13] As a result, a highly sensitive analytical technique is required. To date, a variety of techniques have been utilized to analyze AA neurotransmitters in the microdialysate such as biosensors, [14] microchip electrophoresis, [15] CE-LIF, [16] LC-MS, [17] HPLC, [18,19] etc… Among these, HPLC is most common due to its advantages in operation, cost, and repeatability. Fluorescence detector (FLD) is most widely used in the HPLC detection of AA neurotransmitters, [20][21][22] but the electrochemical detector (ECD) is a better choice partly because of its sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…Blood samples were drawn for norfloxacin high-performance liquid chromatography determinations in plasma (2). Dialysates were collected every 15 min for glutamate determinations (8). PK-PD modeling was conducted as previously described (2).…”
mentioning
confidence: 99%
“…A detectabilidade do detector acoplado no cromatógrafo líquido de alta eficiência foi um importante parâmetro avaliado neste estudo, já que os aminoácidos A desvantagem deste reagente é a instabilidade dos derivativos isoindoles formados em temperatura ambiente sendo necessário limitar seu tempo de reação (RABOUAN et al, 2003). Neste contexto, para se conseguir uma reprodutibilidade alta o derivativo formado permaneceu exatamente por 3 minutos em temperatura ambiente.…”
Section: Otimização Da Detecção Dos Analitosunclassified