Validation of the i-STAT and HemoCue systems for the analysis of blood parameters in the bar-headed goose,Anser indicus

Abstract: Our results indicate that the i-STAT and HemoCue systems can be useful tools to measure many (but not all) blood-gas and acid-base variables in the bar-headed goose. The accuracy of generated results can be improved by using the correction equations provided here, although extrapolation beyond the tested conditions should be avoided.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
21
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(21 citation statements)
references
References 23 publications
0
21
0
Order By: Relevance
“…[Hb] (g dl −1 ), Hct (%), arterial partial pressure of oxygen (Pa O2 ; kPa), arterial pH ( pH a ) and arterial bicarbonate ion concentration ([HCO 3 − ] a ; mmol l −1 ) were analysed from arterial blood at 41°C using CG8+ cartridges with the i-STAT VetScan Analyzer (Abaxis, Union City, CA, USA). All i-STAT values were corrected according to Harter et al (2015). We used the correction factors determined for bar-headed geese for all species, assuming that these corrections should apply for all nucleated bird blood.…”
Section: Measurementsmentioning
confidence: 99%
“…[Hb] (g dl −1 ), Hct (%), arterial partial pressure of oxygen (Pa O2 ; kPa), arterial pH ( pH a ) and arterial bicarbonate ion concentration ([HCO 3 − ] a ; mmol l −1 ) were analysed from arterial blood at 41°C using CG8+ cartridges with the i-STAT VetScan Analyzer (Abaxis, Union City, CA, USA). All i-STAT values were corrected according to Harter et al (2015). We used the correction factors determined for bar-headed geese for all species, assuming that these corrections should apply for all nucleated bird blood.…”
Section: Measurementsmentioning
confidence: 99%
“…were determined at 41°C using the Tucker method (Tucker, 1967) cartridges with the i-STAT VetScan Analyzer (Abaxis, Union City, CA, USA). All i-STAT values were corrected according to Harter et al (2015). [HCO 3 − ] a was calculated using the HendersonHasselbach equation, assuming a pK of 6.090 and a CO 2 solubility coefficient of 0.2117 mmol l −1 kPa −1 in plasma (Helbecka et al, 1964;Scott and Milsom, 2007).…”
Section: Measurementsmentioning
confidence: 99%
“…We corrected the Hct and [Hb] data collected by the i-STAT VetScan Analyzer for all groups based on the calibrations derived for bar-headed geese in Harter et al (2015). Data are presented as means±s.e.m.…”
Section: Data and Statistical Analysismentioning
confidence: 99%
“…We do not consider high‐elevation mountain crossings, such as trans‐Himalayan migrations (e.g., Harter et al. ), to be altitudinal migration.…”
mentioning
confidence: 99%