2019
DOI: 10.1016/j.exer.2019.107698
|View full text |Cite
|
Sign up to set email alerts
|

Validation of the Icare® TONOVET plus rebound tonometer in normal rabbit eyes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

11
51
2

Year Published

2020
2020
2025
2025

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 23 publications
(64 citation statements)
references
References 18 publications
11
51
2
Order By: Relevance
“…The degree to which the Tono‐Pen Vet™ and Tono‐Pen AVIA Vet™ underestimate high IOP is striking and is an important clinical consideration, pertinent to the diagnosis of glaucoma. Fortunately, since IOP data obtained with all tonometers linearly correlated with manometric IOP, more accurate estimates of true IOP can likely be derived by applying the linear regression equations reported here, and as suggested by previous studies 16,19,21,25 . Ultimately, however, patient history and clinical signs should be considered when interpreting IOP measurements and ideally the same device should be used when taking serial IOP measurements and/or when monitoring for longitudinal changes in IOP, for example, in response to therapy in a clinical setting.…”
Section: Discussionmentioning
confidence: 69%
See 1 more Smart Citation
“…The degree to which the Tono‐Pen Vet™ and Tono‐Pen AVIA Vet™ underestimate high IOP is striking and is an important clinical consideration, pertinent to the diagnosis of glaucoma. Fortunately, since IOP data obtained with all tonometers linearly correlated with manometric IOP, more accurate estimates of true IOP can likely be derived by applying the linear regression equations reported here, and as suggested by previous studies 16,19,21,25 . Ultimately, however, patient history and clinical signs should be considered when interpreting IOP measurements and ideally the same device should be used when taking serial IOP measurements and/or when monitoring for longitudinal changes in IOP, for example, in response to therapy in a clinical setting.…”
Section: Discussionmentioning
confidence: 69%
“…Both represent good options as they are handheld, portable, and lightweight; however, the ICare ® TV01 is particularly useful for veterinary clinicians and those doing research in animal models as topical anesthesia is not required to obtain measurements. A multitude of research studies have been conducted, validating the use of the Tono‐Pen VET™ and the ICare ® TV01 in dogs, 1,3,7‐13 cats, 11,14‐16 horses, 12,17 rabbits, 18,19 macaques, 20,21 and in various other species 22‐25 . In previous studies, both the TV01 and Tono‐Pen have been found to underestimate IOP in dogs 3,10,13 …”
Section: Introductionmentioning
confidence: 95%
“…Validation of this device has been reported not only for dogs but also for mice, monkeys, pigeons, birds of preys, and rabbits 12,15,26‐28 . Other rebound tonometers such as TONOVET‐Plus ® and SW‐500 ® have been recently used for laboratory animals 29,30 . IOP values measured with the rebound tonometer could be affected by differences in the biomechanical properties of the cornea between species 16,17,31 ; therefore, studies are being conducted to verify the accuracy of these instruments in each species.…”
Section: Discussionmentioning
confidence: 99%
“…To the authors' knowledge, no published studies on the use of Tonovet Plus ® in horses are available to date. A single study performed in rabbits states the accuracy of Tonovet ® Plus to be improved compared with Tonovet ® 16 . In addition, a recent study compared the two devices in healthy dogs and found 4.2 mm Hg higher average readings with Tonovet Plus ® than with Tonovet ® 17 .…”
Section: Introductionmentioning
confidence: 99%