Validation of the LC-MS/MS method for the quantification of mevalonic acid in human plasma and determination of the matrix effect

Abstract: A simple, specific, and sufficiently sensitive liquid chromatography-tandem mass spectrometry (negative-ion electrospray ionization) methodology to determine mevalonic acid (MVA) in human plasma is described, and its application to the analysis of rat plasma MVA levels after rosuvastatin administration is demonstrated. The method was validated over the linearity range of 0.5-50.0 ng/ml (r 2 . 0.99) using deuterated MVA as an internal standard. The lower limit of quantification was 0.5 ng/ml. The assay procedur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
31
0
3

Year Published

2007
2007
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(34 citation statements)
references
References 17 publications
0
31
0
3
Order By: Relevance
“…The assay was also not affected by fl uvastatin, simvastatin, modifi cation ( 10 ). The system is comprised of an API-3200 mass spectrometer (AB SCIEX; Foster, CA) equipped with a LC20A liquid chromatography system (Shimadzu; Kyoto, Japan).…”
Section: Interference Study By Serum Substances and Statin Drugsmentioning
confidence: 99%
See 1 more Smart Citation
“…The assay was also not affected by fl uvastatin, simvastatin, modifi cation ( 10 ). The system is comprised of an API-3200 mass spectrometer (AB SCIEX; Foster, CA) equipped with a LC20A liquid chromatography system (Shimadzu; Kyoto, Japan).…”
Section: Interference Study By Serum Substances and Statin Drugsmentioning
confidence: 99%
“…These include a radioenzyme assay ( 2 ), enzyme immunoassay ( 3 ), GC-MS assay ( 4-7 ), and LC-MS/MS assay (8)(9)(10)(11)(12)(13). Until now, however, the use of enzymatic spectrophotometric methodology has been precluded by the extremely low levels of MVA in human plasma and serum.…”
mentioning
confidence: 99%
“…D-7 was the internal standard and read as m/z 154/59. The concentrations were read using Analyst® software (13).…”
Section: Estimation Of Serum Mvamentioning
confidence: 99%
“…These methods involve enzymatic method, 19 enzyme immunoassay, 20 radioimmunoassay, 21,22 GC-MS methods 3,[23][24][25] and LC-MS/MS assay. [26][27][28][29][30][31] However, their disadvantage is due to the expense of equipment, extensive sample preparation, time consuming, complications as well as radioactive materials. Hence, there is a need for developing a new method, which should be rapid, sensitive, specific, cost effective and preferable at the point of sample collection.…”