Validation Study of PulseCO System for Continuous Cardiac Output Measurement

Abstract: Ultrasonic flow probes have been used to optimize biventricular pacing immediately after cardiopulmonary bypass, improving cardiac output (CO) by 10%; however, flow probes must be removed with chest closure. The PulseCO system (LiDCO Limited, Cambridge, UK) may extend optimization into the postoperative period, but controlled validations have not been reported. Six anesthetized pigs were instrumented for right heart bypass. Flow was varied from 3 to 1 L/min and then back to 3 in 0.5 L/min increments for 60 sec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
15
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(16 citation statements)
references
References 7 publications
1
15
0
Order By: Relevance
“…This report demonstrates in obstetric patients a new cardiovascular monitoring technology called pulse contour or pulse power analysis (PulseCO system, LiDCO Ltd. Cambridge, UK) that allows MAP, SVR and CO to be monitored in real time with only an arterial line. [6][7][8][9][10][11] Formal calibration by lithium dilution can be performed to obtain correct absolute values for SVR and CO, but, as in the present case series, trends in predicted, or nominal, hemodynamic values can be followed without resorting to the somewhat laborious calibration procedure. The nominal hemodynamic values are derived in real time from the arterial pressure waveform and algorithms that use the patient's height, weight and age to predict aortic compliance.…”
Section: Introductionmentioning
confidence: 99%
“…This report demonstrates in obstetric patients a new cardiovascular monitoring technology called pulse contour or pulse power analysis (PulseCO system, LiDCO Ltd. Cambridge, UK) that allows MAP, SVR and CO to be monitored in real time with only an arterial line. [6][7][8][9][10][11] Formal calibration by lithium dilution can be performed to obtain correct absolute values for SVR and CO, but, as in the present case series, trends in predicted, or nominal, hemodynamic values can be followed without resorting to the somewhat laborious calibration procedure. The nominal hemodynamic values are derived in real time from the arterial pressure waveform and algorithms that use the patient's height, weight and age to predict aortic compliance.…”
Section: Introductionmentioning
confidence: 99%
“…Experiments in pigs showed good agreement between LiDCO and PulseCO over a CO range of three L/min to one L/min, but only after sufficient time had passed (roughly 30 sec) to allow the MAP to stabilize at its new level [20].…”
Section: Discussionmentioning
confidence: 98%
“…The PCCO is a temperature-independent method of calculating changes in CO obtained from analysis of the arterial catheter waveform. A validation study of PCCO for continuous CO measurement has been reported (22). The PCCO was calibrated to CO from the PAC when SCDs were deflated before the start of the study.…”
Section: Methodsmentioning
confidence: 99%