2023
DOI: 10.1371/journal.pone.0282395
|View full text |Cite
|
Sign up to set email alerts
|

Validity and intrarater reliability of a novel device for assessing Plantar flexor strength

Abstract: Introduction Plantar flexor weakness is an identified prospective factor for developing Achilles tendinopathy. Various authors have reported relationships between symptoms and weakness of this muscle group. Despite this relationship, many clinicians and researchers fail to examine Plantar flexor strength due to the cumbersome, stationary and expensive nature of an isokinetic dynamometer (IKD), known as the “Gold Standard”. This study examined the validity and reliability of a fast, easy and portable device for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 49 publications
0
4
0
Order By: Relevance
“…Half of surveyed strength and conditioning coaches working in football use force plates to regularly assess the force-generating capabilities of their athletes [10]. Force plates have only been used to assess isometric plantar flexion force in studies published since 2022 [11][12][13][14][15][16][17][18][19][20]. Only one study involved football players and included the seated isometric plantar flexor test (SIPFT) to determine its reliability of quantifying peak force [20].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Half of surveyed strength and conditioning coaches working in football use force plates to regularly assess the force-generating capabilities of their athletes [10]. Force plates have only been used to assess isometric plantar flexion force in studies published since 2022 [11][12][13][14][15][16][17][18][19][20]. Only one study involved football players and included the seated isometric plantar flexor test (SIPFT) to determine its reliability of quantifying peak force [20].…”
Section: Introductionmentioning
confidence: 99%
“…Despite the abovementioned limitations of the SIPFT protocol utilized by Rhodes et al [20], several other researchers have adopted a similar approach to assessing the isometric peak force capabilities of the plantar flexors [11,[13][14][15][16][17]19]. An alternative approach to conducting the SIPFT, whereby a novel device specifically designed to assess the isometric force capabilities of the plantar flexors was validated [18] and used to assess a large cohort of rugby players, was recently published, thus providing normative reference values [12]. The strengths of the custom device and setup included the removal of a soft foam pad by using ratchet straps to fix the leg in position, thus removing the pad compression issue, and the test was conducted unilaterally, thus overcoming the bilateral strength deficit issue [21].…”
Section: Introductionmentioning
confidence: 99%
“…Half of surveyed strength and conditioning coaches working in football use force plates to regularly assess the force-generating capabilities of their athletes [10]. Force plates have only been used to assess isometric plantar flexion force in studies published since 2022 [11][12][13][14][15][16][17][18][19][20]. Only one study involved football players and included the seated isometric plantar flexor test (SIPFT) to determine its reliability of quantifying peak force [20].…”
Section: Introductionmentioning
confidence: 99%
“…Despite the abovementioned limitations of the SIPFT protocol utilized by Rhodes et al [20], several other researchers have adopted a similar approach to assessing the isometric peak force capabilities of the plantar flexors [11,[13][14][15][16][17]19]. An alternative approach to conducting the SIPFT, whereby a novel device specifically designed to assess the isometric force capabilities of the plantar flexors was validated [18] and used to assess a large cohort of rugby players, was recently published, thus providing normative reference values [12]. The strengths of the custom device and setup included the removal of a soft foam pad by using ratchet straps to fix the leg in position, thus removing the pad compression issue, and the test was conducted unilaterally, thus overcoming the bilateral strength deficit issue [21].…”
Section: Introductionmentioning
confidence: 99%