Validity and Reliability of Free Software for Bidimentional Gait Analysis

Abstract: | Introduction:Despite the evaluation of technology in human movement evaluation, the high cost and specific training of these kind of technology are not feasible for clinical practice. An ideal videogrammetry system should be easy to use, low cost, with minimal equipment, and fast realization. Objective: This paper aims to determine if CvMob is a reliable tool for the evaluation of bidimensional human gait. Methods and materials: The sample was composed of 56 healthy individuals who were simultaneously filmed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 25 publications
0
5
0
1
Order By: Relevance
“… Kinematic parameters extracted from video recordings: gait velocity (cm/sec), gait duration (sec), cadence (steps/min), stride, and step lengths (cm), percentage of time in the stance/swing phase, and body sway variability in the anterior-posterior and medial-lateral planes (cm). Open-source software for computer vision analysis of human movement (CvMob; Peña et al, 2013 ; Gea et al, 2014 ; Quixadá et al, 2016 ) was used to extract those variables. This software has a high degree of accuracy for calculating body position and movement in the X and Y coordinates recorded by conventional cameras (Peña et al, 2013 ).…”
Section: Methodsmentioning
confidence: 99%
“… Kinematic parameters extracted from video recordings: gait velocity (cm/sec), gait duration (sec), cadence (steps/min), stride, and step lengths (cm), percentage of time in the stance/swing phase, and body sway variability in the anterior-posterior and medial-lateral planes (cm). Open-source software for computer vision analysis of human movement (CvMob; Peña et al, 2013 ; Gea et al, 2014 ; Quixadá et al, 2016 ) was used to extract those variables. This software has a high degree of accuracy for calculating body position and movement in the X and Y coordinates recorded by conventional cameras (Peña et al, 2013 ).…”
Section: Methodsmentioning
confidence: 99%
“…A three-dimensional kinematic system can also measure oscillations in the three planes 27 . However, free software was not found for this analysis, and its use in the research environment is too costly to be adopted as the gold standard on an outpatient basis.…”
Section: Discussionmentioning
confidence: 99%
“…The kinematic gait variables were measured with the CvMob™ movement analysis system ( 30 , 39 ). Of the variables analyzed in the study, only the velocity in the Y-axis (VyMedio) was extracted directly from the CvMob™ program.…”
Section: Methodsmentioning
confidence: 99%