Validity and reliability of Polar® RS800CX heart rate monitor, measuring heart rate in dogs during standing position and at trot on a treadmill

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
59
1
3

Year Published

2015
2015
2021
2021

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 70 publications
(66 citation statements)
references
References 32 publications
0
59
1
3
Order By: Relevance
“…Artefacts were defined as extreme values lower than 30 or higher than 250 bpm. It has been shown recently that uncorrected Polar® data show excellent accordance to ECG data [41]. Even though there are algorithms to correct dog heart rate data [42], it is still difficult to disentangle other artefacts than extreme values (i.e.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Artefacts were defined as extreme values lower than 30 or higher than 250 bpm. It has been shown recently that uncorrected Polar® data show excellent accordance to ECG data [41]. Even though there are algorithms to correct dog heart rate data [42], it is still difficult to disentangle other artefacts than extreme values (i.e.…”
Section: Discussionmentioning
confidence: 99%
“…Perhaps due to their lack of experience, lab dogs may perceive these expressions as ambiguous (c.f. [41]). Due to the need for further evaluation of such facial expressions, the dog gets aroused and the heart rate is accelerated.…”
Section: Influence Of the Emotional Expression On The Heart Ratementioning
confidence: 99%
“…During the training all dogs were wearing a Polar © RS800CX heart rate monitor (Polar Electro Oy, Kempele, Finland) consisting of a watch, receiving and storing the data, and an electrode belt and transmitter (Polar, Wear Link Smart Fabric sensor W.I.N.D © ), which has been shown to reliably measure heart rate in dogs (Essner et al, 2013). This device measures heart beats at a frequency of 1000 Hz with a transfer rate of 2.4 GHz between belt and heart rate monitor.…”
Section: Methodsmentioning
confidence: 99%
“…The study protocol was reviewed and approved by the Colorado State University Institutional Animal Care and Use Committee (#14-4908A) and written owner consent was obtained. Stress monitoring of the dogs was performed by behavioral assessment and by utilizing a heart rate monitor (Polar Ft1 Heart Rate Monitor, Polar Electro Inc) (Cohen and Obrist, 1975;Vincent and Leahy, 1997;Beerda et al, 1998;Essner et al, 2013). Dogs showing an obvious, strong stress-response during the study were to be excluded.…”
Section: Animalsmentioning
confidence: 99%