2019
DOI: 10.1080/19424280.2019.1614098
|View full text |Cite
|
Sign up to set email alerts
|

Validity of an instrumented sock and on-shoe sensor to provide biometric feedback to runners

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…The sensors are connected to the Sensoria Core, a small, rigid electronics module that snaps into the dock located at the top of the sock. In comparison with a shoe-based inertial sensor and video analysis, the smart sock provided an excellent measure of cadence (ICC 0.91), speed (ICC 0.86), distance (ICC 0.86) and foot strike pattern (ICC 0.91) [ 136 ]. Fabric-embedded electrodes are used in the Athos Core compression garment designed to monitor muscle excitation alongside heart and breath rates.…”
Section: Commercialised Wearable Technologies For Sportsmentioning
confidence: 99%
“…The sensors are connected to the Sensoria Core, a small, rigid electronics module that snaps into the dock located at the top of the sock. In comparison with a shoe-based inertial sensor and video analysis, the smart sock provided an excellent measure of cadence (ICC 0.91), speed (ICC 0.86), distance (ICC 0.86) and foot strike pattern (ICC 0.91) [ 136 ]. Fabric-embedded electrodes are used in the Athos Core compression garment designed to monitor muscle excitation alongside heart and breath rates.…”
Section: Commercialised Wearable Technologies For Sportsmentioning
confidence: 99%
“…However, when there was a change in the foot strike pattern combined with an increase in cadence, the anterior displacement of the center of pressure was significantly more pronounced, which suggested that the average location of the center of pressure along the longitudinal axis of the insole changed by 192.7% in relation to the baseline. According to Stoltenberg et al [71], the sensor-instrumented socks demonstrated moderate reliability for the detection of the foot strike pattern and excellent reliability in determining cadence. In a study by Musgierd et al [59] that used insoles with sensors to collect cadence and peak force, it was identified that a 7.3% increase in cadence generated a decrease in the peak force of 5.6%.…”
Section: Effectiveness Of Lower-cost Equipment For Alterations In Spa...mentioning
confidence: 99%
“…Cadence was preset to 180 steps/minute (McDougall, 2009;Diebal et al, 2012) and participants were provided cues when they dropped below 180 steps per minute for a percentage of the run. The socks have demonstrated moderate FSP reliability and excellent cadence reliability (Stoltenberg et al, 2019). An online account was generated for each participant to track usage of the socks.…”
Section: Interventionmentioning
confidence: 99%