2023
DOI: 10.21037/qims-22-979
|View full text |Cite
|
Sign up to set email alerts
|

Value of spectral computed tomography-derived quantitative parameters based on full volume analysis in the diagnosis of benign/malignant and pathological subtypes of solitary pulmonary nodules

Abstract: Background: Conventional dynamic computed tomography (CT) has a low specificity for the distinction between benign and malignant solitary pulmonary nodules (SPNs), and spectral CT has been proposed as a potential alternative. We aimed to investigate the role of quantitative parameters based on full-volume spectral CT in the differential diagnosis of SPNs.Methods: This retrospective study included spectral CT images of 100 patients with pathologically confirmed SPNs (78 and 22 in the malignant and benign groups… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 38 publications
(65 reference statements)
0
1
0
Order By: Relevance
“…The following values were recorded in our study: The CT values of the lesions at virtual non-contrast (VNC) and enhancement (40 and 70 keV), which were recorded as CT SPN-VNC , CT SPN-40keV , and CT SPN-70keV , respectively; and the CT values of the aorta at VNC (CT aorta-VNC ) and enhancement at 70 keV (CT aorta ), which were recorded and used as references. The following formulas were used to calculate the lesion to aorta virtual plain scan ratio (SAR VNC ), the lesion to aorta enhancement ratios (SAR 40keV and SAR 70keV ), the differences between the lesion enhancement and virtual plain scan CT value (Δ 40keV and Δ 70keV ), the contrast enhancement ratios (CER 40keV and CER 70keV ), the standardized reinforcement scores (NEF 40keV and NEF 70keV ), and λ ( 23 , 24 ):…”
Section: Methodsmentioning
confidence: 99%
“…The following values were recorded in our study: The CT values of the lesions at virtual non-contrast (VNC) and enhancement (40 and 70 keV), which were recorded as CT SPN-VNC , CT SPN-40keV , and CT SPN-70keV , respectively; and the CT values of the aorta at VNC (CT aorta-VNC ) and enhancement at 70 keV (CT aorta ), which were recorded and used as references. The following formulas were used to calculate the lesion to aorta virtual plain scan ratio (SAR VNC ), the lesion to aorta enhancement ratios (SAR 40keV and SAR 70keV ), the differences between the lesion enhancement and virtual plain scan CT value (Δ 40keV and Δ 70keV ), the contrast enhancement ratios (CER 40keV and CER 70keV ), the standardized reinforcement scores (NEF 40keV and NEF 70keV ), and λ ( 23 , 24 ):…”
Section: Methodsmentioning
confidence: 99%