Abstract:Vapor-liquid equilibrium measurements have been carried out for the propane-ethanol system at 325O, 350°, 375O, 400°, and 425OK. The pressures corresponding to these temperatures ranged from 569.5 kPa (82.6 lb/ in.2abs) to 5 618.5 kPa (814.9 lb/in.Zabs). Altogether, nineteen experimental determinations were made; one of these determinations at 425OK approached the critical state, and this measurement assisted in establishing the entire critical temperature and critical pressure profiles for this binary system.… Show more
“…For this reason the liquid-phase analysis is performed first. For the system propane (l)-ethanol (2) our liquid-phase results disagree with those from Gomez-Nieto and Thodos (8). They obtained higher liquid-phase propane concentrations at fixed T, P coordinates.…”
Section: Resultscontrasting
confidence: 88%
“…(5) hydrocarbon feeding line; (6) liquid-phase purging line; (7) filter; (8) filter; (9) four-way valve; (10) ten-way valve; (11) stirring magnet; (12) thermistor probe (to the temperature indicator); (2) vapor-phase sampling line; (3) feeding line; (4) alcohol feeding line; (5) hydrocarbon feeding line; (6) liquid-phase purging line; (9) four-way valve; (10) ten-way line (Figure 1). This line is covered with a heating tape, from the outlet of the liquid valve to the chromatograph injection port.…”
Section: Experimental Methods and Apparatusmentioning
confidence: 99%
“…Figure1. Equilibrium cell: (V1-V5) valves; (1) liquid-phase sampling line; (2) vapor-phase sampling line; (3) feeding line;(4) alcohol feeding line;(5) hydrocarbon feeding line;(6) liquid-phase purging line;(7) filter;(8) filter;(9) four-way valve; (10) ten-way valve;(11) stirring magnet;(12) thermistor probe (to the temperature indicator);(13) glass window; (14) Viton O-ring; (15) Teflon washer; (16) pressing cylinder; (17) cell body; (18) aluminum shell; (19) heating resistances; (20) magnetic stirrer; (21) pressure measurement line; (22) temperature controller thermistor well; (23) electric contacts; (24) carrier gas inlet; (25) carrier gas outlet. The thermal insulation is not shown.…”
“…For this reason the liquid-phase analysis is performed first. For the system propane (l)-ethanol (2) our liquid-phase results disagree with those from Gomez-Nieto and Thodos (8). They obtained higher liquid-phase propane concentrations at fixed T, P coordinates.…”
Section: Resultscontrasting
confidence: 88%
“…(5) hydrocarbon feeding line; (6) liquid-phase purging line; (7) filter; (8) filter; (9) four-way valve; (10) ten-way valve; (11) stirring magnet; (12) thermistor probe (to the temperature indicator); (2) vapor-phase sampling line; (3) feeding line; (4) alcohol feeding line; (5) hydrocarbon feeding line; (6) liquid-phase purging line; (9) four-way valve; (10) ten-way line (Figure 1). This line is covered with a heating tape, from the outlet of the liquid valve to the chromatograph injection port.…”
Section: Experimental Methods and Apparatusmentioning
confidence: 99%
“…Figure1. Equilibrium cell: (V1-V5) valves; (1) liquid-phase sampling line; (2) vapor-phase sampling line; (3) feeding line;(4) alcohol feeding line;(5) hydrocarbon feeding line;(6) liquid-phase purging line;(7) filter;(8) filter;(9) four-way valve; (10) ten-way valve;(11) stirring magnet;(12) thermistor probe (to the temperature indicator);(13) glass window; (14) Viton O-ring; (15) Teflon washer; (16) pressing cylinder; (17) cell body; (18) aluminum shell; (19) heating resistances; (20) magnetic stirrer; (21) pressure measurement line; (22) temperature controller thermistor well; (23) electric contacts; (24) carrier gas inlet; (25) carrier gas outlet. The thermal insulation is not shown.…”
“…(9) cell body; (10) brass support for pressure transducer; (11) PVC tube; (12) glass window; (13) Teflon washer; (14) Viton O-ring; (15) copper gasket. magnetic circuit immersed in the thermostatic bath, was used for this purpose.…”
Section: Experimental Methods and Apparatusmentioning
“…Comparison of the VLE at 350 K and 450 K of the system ethanol(1)-propane(2) (squares[78]) computed with the VTPR EOS using the COSMO-RS model via different MRs with experimental data. The values for the internal parameters of the 1P, the 3P and the WS MR are given inTable 1.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.