2009
DOI: 10.1021/je8010024
|View full text |Cite
|
Sign up to set email alerts
|

Vapor Pressure of Organophosphorus Nerve Agent Simulant Compounds

Abstract: The vapor pressures of four lower alkyl phosphonate compounds, dimethyl phosphonate (DMHP, CAS 868-85-9), dimethyl methylphosphonate (DMMP, CAS 756-79-6), diethyl methylphosphonate (DEMP, CAS 683-08-9), and diisopropyl methylphosphonate (DIMP, CAS 1445-75-6), have been measured by complementary methods that allow data collection at ambient and high temperatures by use of gas saturation and differential scanning calorimetry, respectively. Kosolapoff (J. Chem. Soc.195529642965) reported vapor pressure data above… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
100
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 93 publications
(105 citation statements)
references
References 16 publications
5
100
0
Order By: Relevance
“…Differential scanning calorimetry (DSC) has been used to determine the vapour pressure of diverse compounds, for instance, alkyl phosphonates [ 19 ], ethyl esters [ 20 ], 2-dialkyl aminoethanethiols [ 21 ], fatty acids [ 22 ] and precursors of chemical warfare agents [ 23 ]. In DSC, the isothermal boiling temperature of a pure compound is measured as a function of pressure.…”
Section: Methodsmentioning
confidence: 99%
“…Differential scanning calorimetry (DSC) has been used to determine the vapour pressure of diverse compounds, for instance, alkyl phosphonates [ 19 ], ethyl esters [ 20 ], 2-dialkyl aminoethanethiols [ 21 ], fatty acids [ 22 ] and precursors of chemical warfare agents [ 23 ]. In DSC, the isothermal boiling temperature of a pure compound is measured as a function of pressure.…”
Section: Methodsmentioning
confidence: 99%
“…The saturated vapor pressure can be calculated by using the Antoine equation: ln(P0)=ABC+Twhere P 0 is the saturated vapor pressure; A , B and C are empirical Antoine constants; T is the thermodynamic temperature. If P 0 in Pascal, the Antoine constants of DMMP [28] are A = 22.319, B = 4,344.0 and C = −51.7. In this work, the temperature of the SAW detector is controlled at 25 °C ( T = 298.15 K), substituting these parameters into Equation (10) we can get P 0 = 111 Pa.…”
Section: Experimental Verificationmentioning
confidence: 99%
“…6 Within the recommended ASTM pressure range down to 5 kPa, method uncertainty is + 1 K. At 1330 Pa, the larger pinholes yielded boiling points within 2 K of literature values. This decreased accuracy remains an area of further study.…”
mentioning