1999
DOI: 10.21236/ada371297
|View full text |Cite
|
Sign up to set email alerts
|

Vapor Pressure of VX

Abstract: Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
44
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 19 publications
(44 citation statements)
references
References 1 publication
0
44
0
Order By: Relevance
“…Measured data included the mixture dew point temperature and ambient pressure. The methods and materials for measuring these parameters have been described in detail in previous reports [1,2]. Briefly, calibrated thermometers were used to measure bath temperatures and are believed to be accurate within 0.1 • C, and flow rates were measured using factory-calibrated electronic mass-flow controllers (Tylan General, San Diego, California).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Measured data included the mixture dew point temperature and ambient pressure. The methods and materials for measuring these parameters have been described in detail in previous reports [1,2]. Briefly, calibrated thermometers were used to measure bath temperatures and are believed to be accurate within 0.1 • C, and flow rates were measured using factory-calibrated electronic mass-flow controllers (Tylan General, San Diego, California).…”
Section: Methodsmentioning
confidence: 99%
“…The vapor pressures of dimethyl methylphosphonate (DMMP) [1] and a number of chemical warfare agents, e.g., O-ethyl-2-(isopropylaminoethyl) methyl phosphonothiolate (VX) [2,3] and cyclohexyl methylphosphonofluoridate (GF) [4], have been measured in the ambient temperature range recently. So far, that work has not included effects of atmospheric water vapor.…”
Section: Introductionmentioning
confidence: 99%
“…Vapor saturation measurements were conducted using the apparatus described previously, 8 including a Hewlett Packard Model 5890 Series II gas chromatograph (GC) equipped with a flame ionization detector (FID) as described in detail in an earlier report from our laboratory. 9 The glass saturator used in this effort was custom designed at the U.S. Army Edgewood Chemical Biological Center (ECBC).…”
Section: Vapor Saturationmentioning
confidence: 99%
“…These readings were used in the vapor pressure calculation as described previously. 8 No corrections were included for the pressure drop between the sampling location and ambient. This correction is expected to be minimal because the flow stream was open to the atmosphere and there were no flow restrictions.…”
Section: Vapor Saturationmentioning
confidence: 99%
See 1 more Smart Citation