Variable-Velocity Traveling-Wave Ion Mobility Separation Enhancing Peak Capacity for Data-Independent Acquisition Proteomics

Abstract: High mass accuracy, data-dependent acquisition is the current standard method in mass spectrometry-based peptide annotation and quantification. In high complexity samples, limited instrument scan speeds often result in under-sampling. In contrast, all-ion data-independent acquisition methods bypass precursor selection, alternating high and low collision energies to analyze product and precursor ions across wide mass ranges. Despite capturing data for all events, peptide annotation is limited by inadequate alig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
87
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 81 publications
(88 citation statements)
references
References 16 publications
0
87
0
1
Order By: Relevance
“…Native mass spectra were calibrated externally using a solution of cesium iodide (100 mg/mL) and processed with Masslynx V4.1 software (Waters, Milford, MA). CIU data was extracted using TWIMExtract and analyzed using the CIUSuite to generate CIU plots and perform CIU comparisons. Root‐mean‐square deviation (RMSD) values were computed from a pixel‐to‐pixel comparison of two CIU fingerprints.…”
Section: Methodsmentioning
confidence: 99%
“…Native mass spectra were calibrated externally using a solution of cesium iodide (100 mg/mL) and processed with Masslynx V4.1 software (Waters, Milford, MA). CIU data was extracted using TWIMExtract and analyzed using the CIUSuite to generate CIU plots and perform CIU comparisons. Root‐mean‐square deviation (RMSD) values were computed from a pixel‐to‐pixel comparison of two CIU fingerprints.…”
Section: Methodsmentioning
confidence: 99%
“…Raw data were analyzed using MassLynx (Waters). ATDs for all CCS calibrants as well as ScSERF complex samples were extracted from raw data using TWIMExtract (49), and IM ATDs were fit to Gaussian functions using CIUSuite2 (50).…”
Section: ½M ½Mmentioning
confidence: 99%
“…Analysis and visualization of nESI(-IM)-MS data was done using Masslynx V4.1 (Waters Corporation, Wilmslow, UK) and Origin 8.0 (OriginLab Corporation, Northampton, MA, USA). Further analysis of CIU plots was performed using TWIMExtract and CIUSuite 2 [ 57 , 58 ].…”
Section: Methodsmentioning
confidence: 99%