2004
DOI: 10.1002/jbm.b.30036
|View full text |Cite
|
Sign up to set email alerts
|

Variation in surface texture measurements

Abstract: Surface texture influences cellular response to implants, implant wear, and fixation, yet measurement and reporting of surface texture can be confusing and ambiguous. Seven specimens of widely different surface textures were submitted to three internationally renowned laboratories for surface texture characterization. The specimens were from dental implants, orthopedic implants, and femoral heads. Areas to be measured were clearly marked; simplified instructions were supplied but specific measurement parameter… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(17 citation statements)
references
References 25 publications
0
17
0
Order By: Relevance
“…Ra was calculated for each sample ''Ra: is the arithmetic mean of the absolute values of the surface point departures from the mean plane within the sampling area''. 16 Topographic inspection was conducted using scanning electron microscopy (SEM).…”
Section: Surface Topographymentioning
confidence: 99%
“…Ra was calculated for each sample ''Ra: is the arithmetic mean of the absolute values of the surface point departures from the mean plane within the sampling area''. 16 Topographic inspection was conducted using scanning electron microscopy (SEM).…”
Section: Surface Topographymentioning
confidence: 99%
“…In general, the amplitude parameters (R a , R t , R z ) are commonly considered but the frequency and hybrid parameters are more rarely quantified [50]. It should be noted that the current authors compute more than 100 roughness parameters and then statistically correlate these parameters with biological parameters in order to determine the surface parameter(s) to which the cells respond.…”
Section: Response Of Cells To Surface Topographymentioning
confidence: 99%
“…Ra measurement was calculated for each sample: Ra: -is the arithmetic mean of the absolute values of the surface point departures from the mean plane within the sampling area‖ 16 (Macdonald et al, 2004 After verification of the normal distribution and the homogeneity of the variance, an analysis of the variance (ANOVA) was used to asses any significant differences among selected group. For multiple comparisons test (Post Hoc multiple comparisons) LSD (least significant difference) was used to determine the specific differences between the means of the group members.…”
Section: Measurement Of Surface Roughnessmentioning
confidence: 99%