Variation of kQclin,Qmsrfclin,fmsr for the small‐field dosimetric parameters percentage depth dose, tissue‐maximum ratio, and off‐axis ratio

Abstract: Compared with MC simulation, the Exradin W1 PSD can reproduce the PDDs, TMRs, and OARs in water with a high degree of accuracy; thus, the correction used for converting dose is very close to unity. The stereotactic diode is a viable alternative because it shows an acceptable systematic error in the measurement of PDDs and TMRs and a significant underestimation in only the tail region of the OAR measurements, where the dose is low and differences in dose may not be therapeutically meaningful.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

10
130
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 77 publications
(142 citation statements)
references
References 51 publications
10
130
2
Order By: Relevance
“…The air core FOD is a cylindrical scintillation dosimeter with a sensitive volume of 1 mm diameter and 1 mm length, manufactured for use in external beam dosimetry, has been shown to be dosimetrically water‐equivalent, have no directional dependence, and have sufficient spatial resolution for use in field sizes as small as 4 mm in diameter 10 , 19 , 21 . Scintillation dosimeters are a good choice as a reference detector for small field work 15 , 22 as their response has been shown to be independent of dose rate, energy, and temperature, and they provide a linear response with delivered dose 23 , 24 . Scintillation dosimeters have been benchmarked against film 10 , 21 and Monte Carlo (25) and have a smaller measurement uncertainty than film.…”
Section: Methodsmentioning
confidence: 99%
“…The air core FOD is a cylindrical scintillation dosimeter with a sensitive volume of 1 mm diameter and 1 mm length, manufactured for use in external beam dosimetry, has been shown to be dosimetrically water‐equivalent, have no directional dependence, and have sufficient spatial resolution for use in field sizes as small as 4 mm in diameter 10 , 19 , 21 . Scintillation dosimeters are a good choice as a reference detector for small field work 15 , 22 as their response has been shown to be independent of dose rate, energy, and temperature, and they provide a linear response with delivered dose 23 , 24 . Scintillation dosimeters have been benchmarked against film 10 , 21 and Monte Carlo (25) and have a smaller measurement uncertainty than film.…”
Section: Methodsmentioning
confidence: 99%
“…The choice of a particular detector should consider the following: ready availability, multiple independent validations within the literature and with a full validation using Monte Carlo techniques to check for radiological water equivalence. In either situation, detector orientation plays an important role in dose and profile measurements that had been described by Franscescon et el (11) for percent depth dose (PDD), tissue maximum ratio (TMR) and off axis ratio (OAR). There is also a list of detectors and associated kΩ values tabulated by Azangwe et al (21).…”
Section: Detectorsmentioning
confidence: 99%
“…9,14 Owing to their water equivalence and good spatial resolution, plastic scintillation detectors (PSDs) could play an important role in small-field dosimetry. Several authors have studied PSDs in recent years: 10,[15][16][17][18][19][20] their linear response to absorbed dose, dose rate and energy independence are well known. Consequently, PSDs have just found large application in small-field dosimetry.…”
Section: Introductionmentioning
confidence: 99%