2021
DOI: 10.1016/j.bspc.2021.102500
|View full text |Cite
|
Sign up to set email alerts
|

Variation of P-wave indices in paroxysmal atrial fibrillation patients before and after catheter ablation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 53 publications
(62 reference statements)
1
3
0
Order By: Relevance
“…Moreover, there is direct correlation between the increment of λ 1 and the decrement of ρ (Equation (1)). The increment of λ 1 is in line with obtained results in previous studies that showed an increment of P-wave amplitudes and P-wave areas after PVI in ECG recordings [12,13] and simulations [34,35].…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…Moreover, there is direct correlation between the increment of λ 1 and the decrement of ρ (Equation (1)). The increment of λ 1 is in line with obtained results in previous studies that showed an increment of P-wave amplitudes and P-wave areas after PVI in ECG recordings [12,13] and simulations [34,35].…”
Section: Discussionsupporting
confidence: 91%
“…Some studies focused on the spectral content of F waves, of which the dominant frequency was found to significantly decrease during catheter ablation [9], and their related spectral features are useful in predicting the procedure outcome [10]. Further, a decrease in P-wave area is associated with AF recurrence [11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Exposure to RF energy, not only affecting ARV but also MV may be an explanation. Recently a study found MV in lead V1 P-waves of paroxysmal AF undergoing CA of PVs to decrease after the procedure, as a sign of a successful ablation [ 78 ]. Apart from the fact that these results come from P-waves analysis, which in our case show a slight attenuation overall, MV in the present analysis was extracted by a template of the 20 most similar activations and not by considering all activations of one recording.…”
Section: Discussionmentioning
confidence: 99%
“…Hence, P-wave variations after CA reflect changes in the atrial contractility. Many studies have revealed the capability of P-wave parameters such as P-wave duration, amplitude, as well as the frequency domain analysis of assessing the CA outcome [ 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 ]. P-wave duration is probably the most relevant feature, as it measures the duration of the atrial depolarization [ 40 ].…”
Section: Introductionmentioning
confidence: 99%