2016
DOI: 10.1016/j.eats.2016.03.009
|View full text |Cite
|
Sign up to set email alerts
|

Varus-Producing Lateral Distal Femoral Opening-Wedge Osteotomy

Abstract: Valgus knee alignment in excess of physiological valgus leads to excessive loading of the lateral compartment, which can potentially increase the risk of osteoarthritis and can place the medial knee structures at risk of chronic attenuation. Varus-producing distal femoral osteotomies have been proposed for correction of valgus malalignment, to relieve tension on medial-sided structures, as well as to off-load the lateral compartment. Understanding that symptomatic valgus deformity of the knee represents a comp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(12 citation statements)
references
References 22 publications
0
12
0
Order By: Relevance
“…The DFVO procedure was performed through a lateral approach using the technique previously described by Harris et al 5 The degree of correction was determined by calculating the angle between a line extending from the center of the femoral head to the center of the medial tibial spine and a line from the center of the talus through the center of the tibia. 24 The goal of realignment was to place the weight-bearing line at the medial tibial spine. A lowprofile titanium locking plate (Femoral Opening Wedge Osteotomy Plate; Arthrex, Naples, FL) with 4.5-mm threaded cortical screws was used proximally, and 6.5-mm cancellous screws were used for stable fixation.…”
Section: Surgical Techniquementioning
confidence: 99%
“…The DFVO procedure was performed through a lateral approach using the technique previously described by Harris et al 5 The degree of correction was determined by calculating the angle between a line extending from the center of the femoral head to the center of the medial tibial spine and a line from the center of the talus through the center of the tibia. 24 The goal of realignment was to place the weight-bearing line at the medial tibial spine. A lowprofile titanium locking plate (Femoral Opening Wedge Osteotomy Plate; Arthrex, Naples, FL) with 4.5-mm threaded cortical screws was used proximally, and 6.5-mm cancellous screws were used for stable fixation.…”
Section: Surgical Techniquementioning
confidence: 99%
“…The technique utilized for DFVO has previously been described by Mitchell et al 13 The angle formed between a line through the center of the femoral head and the center of the tibial spine and a line passing from the talus through the center of the tibia was measured on the preoperative imaging. The degrees of correction necessary to have the weightbearing line fall over the medial tibial spine were then calculated.…”
Section: Surgical Techniquementioning
confidence: 99%
“…This procedure is commonly performed in combination with other procedures, such as meniscal allograft transplantation (MAT), to address pathologies that might otherwise cause recurrent symptoms. 8,18 The outcomes of this procedure have been relatively positive, 3,11,13 notably providing a mean survival rate of 80% at 10 years, thus being a viable treatment for delaying or reducing the need for knee arthroplasty. 3 In addition, DFVO for symptomatic valgus malalignment has the advantage of no permanent activity restrictions such as those with total knee arthroplasty (TKA), in which modifying activity is paramount to ensure prosthesis durability.…”
mentioning
confidence: 99%
“…A lateral opening-wedge osteotomy effectively creates genu varum to offload the lateral compartment. 39 Studies show good outcomes with this technique, but most patients require conversion to TKA by 20 years. 64…”
Section: Meniscus Transplantationmentioning
confidence: 96%