2016
DOI: 10.17159/2413-3051/2016/v27i3a1556
|View full text |Cite
|
Sign up to set email alerts
|

Varying percentages of full uniform shading of a PV module in a controlled environment yields linear power reduction

Abstract: Partial shading of a PV module has received much attention over the past few years, as it results in

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 34 publications
0
6
0
Order By: Relevance
“…However, the construction of solar energy farms can contribute to climate change. The clearing of forests for solar panel installation contributes to climate change [5,[30][31]. The subsequent decomposition of felled plants results in the release of stored carbon compounds.…”
Section: Solar Energymentioning
confidence: 99%
“…However, the construction of solar energy farms can contribute to climate change. The clearing of forests for solar panel installation contributes to climate change [5,[30][31]. The subsequent decomposition of felled plants results in the release of stored carbon compounds.…”
Section: Solar Energymentioning
confidence: 99%
“…The photovoltaic module defined parameters are maximum voltage, open-circuit voltage, maximum current, short-circuit current, maximum power, fill factor and efficiency. In Figure 2, it is denoted that when the temperature increases from 0 to 75°C, as an immediate consequence, the open-circuit voltage of the photovoltaic module decreases from 40 to 31 V, the maximum power point declines by 55 W and the short-circuit current increases slightly by 0.3 A [30][31][32]. It is also observed that temperature variations have a marginal effect on the I sc , while having a substantial impact on V oc [28,33].…”
Section: Influence Of the Operating Temperature Of The Pv Modulementioning
confidence: 99%
“…It is also observed that temperature variations have a marginal effect on the I sc , while having a substantial impact on V oc [28,33]. The characteristics curve is influenced to different values when photovoltaic modules are exposed to cell damage, radiation change, temperature inequality, local shading and dust, which considerably decreases the output power [30][31][32].…”
Section: Influence Of the Operating Temperature Of The Pv Modulementioning
confidence: 99%
“…The purpose of the conference article or paper is to create awareness among students about the importance of publishing their research results. The official IEEE template is prescribed where students need to focus on their results and preferred solution (recall they suggested three possible solutions in the progress report) (Swart & Hertzog, 2016). Students often struggle to keep to the page limit, while failing to provide an adequate introduction and conclusion to their paper.…”
Section: Study Contextmentioning
confidence: 99%