2012
DOI: 10.2967/jnumed.112.109538
|View full text |Cite
|
Sign up to set email alerts
|

VECTor: A Preclinical Imaging System for Simultaneous Submillimeter SPECT and PET

Abstract: Today, PET and SPECT tracers cannot be imaged simultaneously at high resolutions but require 2 separate imaging systems. This paper introduces a Versatile Emission Computed Tomography system (VECTor) for radionuclides that enables simultaneous submillimeter imaging of single-photon and positron-emitting radiolabeled molecules. Methods: g-photons produced both by electron-positron annihilation and by single-photon emitters are projected onto the same detectors by means of a novel cylindric high-energy collimato… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

4
98
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 102 publications
(102 citation statements)
references
References 31 publications
4
98
0
Order By: Relevance
“…VECTor is a simultaneous SPECT-PET system containing 3 stationary flat-panel NaI(Tl) detectors, 9.5 mm thick (1,3). It is a 511-keV-prepared U-SPECT-II (7) combined with dedicated reconstruction software and shielding.…”
Section: Scanner Descriptionsmentioning
confidence: 99%
See 2 more Smart Citations
“…VECTor is a simultaneous SPECT-PET system containing 3 stationary flat-panel NaI(Tl) detectors, 9.5 mm thick (1,3). It is a 511-keV-prepared U-SPECT-II (7) combined with dedicated reconstruction software and shielding.…”
Section: Scanner Descriptionsmentioning
confidence: 99%
“…These ROIs had equal area and positioning, but the effective slice thickness (after averaging 3 slices) was 0.054 mm. Standardized uptake values (SUVs, units of g/cm 3 ), equal to the ROI mean activity concentration divided by the injected activity per unit body weight, were calculated. Contrasts between striatum and cortex and striatum and septal nucleus were found as the difference in SUV divided by the SUV in the striatum.…”
Section: F-fdg Mouse Brain Imagingmentioning
confidence: 99%
See 1 more Smart Citation
“…There is also a number of commercial tri-modal, pre-clinical PET/SPECT/CT platforms including: Gamma Medica Triumph [2,3], Siemens Inveon [4 -6], MILabs VECTor [7] and Bruker Albira [8 -12]. Table 1 summarises the basic information about PET systems within those three platforms.…”
Section: Introductionmentioning
confidence: 99%
“…Imaging of the highenergy (440 keV) photons is severely compromised for most small-animal SPECT systems, because of the penetration of pinhole edges and the collimator wall. Recently, however, a new dedicated small-animal SPECT system based on use of many clustered pinholes has been developed that enables imaging over an energy range from 25 to 600 keV (10). This system has shown to be able to, for example, image SPECT and PET tracers simultaneously at 0.5-and 0.75-mm resolution, respectively (11).…”
mentioning
confidence: 99%