2015
DOI: 10.1016/j.flowmeasinst.2015.06.006
|View full text |Cite
|
Sign up to set email alerts
|

Velocity measurement for two-phase flows based on ultrafast X-ray tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 36 publications
(12 citation statements)
references
References 17 publications
0
12
0
Order By: Relevance
“…This allows live imaging of the granular flow as well as the measurement of axial velocities in the two detector planes. UFXCT has been demonstrated in several previous applications to provide real-time velocity data of granular ensembles [56,57,[62][63][64]. A more detailed description of the UFXCT principle and the ROFEX (ROssendorf fast electron beam x-ray tomography) setup used here can be found in these publications.…”
Section: Experimental Setup and Materialsmentioning
confidence: 99%
“…This allows live imaging of the granular flow as well as the measurement of axial velocities in the two detector planes. UFXCT has been demonstrated in several previous applications to provide real-time velocity data of granular ensembles [56,57,[62][63][64]. A more detailed description of the UFXCT principle and the ROFEX (ROssendorf fast electron beam x-ray tomography) setup used here can be found in these publications.…”
Section: Experimental Setup and Materialsmentioning
confidence: 99%
“…However, x-ray based techniques are, in general, very constrained by relatively small liquid metal thickness in the beam direction due to intense x-ray attenuation by liquid metals [20][21][22][23][24]. XCT, while offering very high temporal resolution and sufficient phase boundary detection precision, also entails experimental systems that are rather susceptible to applied MF, rendering them hardly applicable to studies of magnetohydrodynamic (MHD) bubble flow [25][26][27].…”
mentioning
confidence: 99%
“…Then, the phase segmentation was performed by adequate thresholding and the phase fraction profiles as well as velocity profiles were calculated. Barthel et al [15], using the same measurement technique, evaluated velocity profile as well. The slice images were reconstructed, with a spatial resolution of approximately 0.6 mm per pixel and were pre-processed by selecting a region of interest, enhancing contrast and removing background.…”
Section: High Energy Rays Tomographymentioning
confidence: 99%