Ventilation inhomogeneity in CDH infants – A new attitude within a simulation study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 51 publications
1
3
0
Order By: Relevance
“…The main study results confirm the pilot study results 9 and indicate the following: there are strong and significant correlations between respiratory system impedance (Z), ventilation parameters (WOB vt , PIP, MAP) and ventilation inhomogeneity degree, described by the T 1 /T 2 index (0.8–0.9, P < 0.001); the correlations are dependent on respiratory rate (RR) and the ratio between chest wall compliance and lung compliance (C W /C L ); these dependencies can be expressed in the form of characteristics consisted of several curves of polynomial functions (Fig. 3 , Supplementary Tables S1 –S5 online); the work of breathing (WOB vt ), PIP, and MAP highly correlate with respiratory system impedance (Z) (0.8–09, P < 0.001) (Fig.…”
Section: Discussionsupporting
confidence: 83%
See 3 more Smart Citations
“…The main study results confirm the pilot study results 9 and indicate the following: there are strong and significant correlations between respiratory system impedance (Z), ventilation parameters (WOB vt , PIP, MAP) and ventilation inhomogeneity degree, described by the T 1 /T 2 index (0.8–0.9, P < 0.001); the correlations are dependent on respiratory rate (RR) and the ratio between chest wall compliance and lung compliance (C W /C L ); these dependencies can be expressed in the form of characteristics consisted of several curves of polynomial functions (Fig. 3 , Supplementary Tables S1 –S5 online); the work of breathing (WOB vt ), PIP, and MAP highly correlate with respiratory system impedance (Z) (0.8–09, P < 0.001) (Fig.…”
Section: Discussionsupporting
confidence: 83%
“…Evaluation of lung inhomogeneity can be accomplished using Multi Breath Washout (MBW), Electrical Impedance Tomography (EIT) or Hyperpolarized 3-Helium Magnetic Resonance Imaging (HP 3-He MRI). However, they are hardly accessible in daily clinical practice due to high costs, extensive workload and the problems with standardization 9 , 14 20 .…”
Section: Discussionmentioning
confidence: 99%