Verification of nose irradiation using orthovoltage x-ray beams

Abstract: Determination of dose distributions from superficial and orthovoltage irradiations of basal cell carcinoma of the nose has been performed using a nose shaped phantom constructed from paraffin wax. EBT type radiochromic film was used for dose measurements. A 2 cm diameter 50 kVp anterior field was used to irradiate the nose phantom, with sheets of film placed at 7 mm, 14 mm and 23 mm physical depth. The percentage depth doses at these points were measured to be 84% +/- 1.6%, 66% +/- 2.7% and 50% +/- 1.2% respec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 16 publications
0
9
0
Order By: Relevance
“…Historically these have included MD-55 and HS film [6][7][8][9][10][11][12] , ISP's films designed specifically for radiotherapy applications where large doses (up to 30 Gy) are required, XR-R films [13][14][15] for high dose diagnostic imaging applications through to films such as XRQA [16][17] which is designed for low dose assessment at kilovoltage x-ray energies. Probably the most used film for radiation dosimetry in therapy applications has been Gafchromic EBT film [18][19][20][21][22][23][24] . Its properties have included lowest energy dependence of any film type dosimeter, radiation sensitivity matched to therapy applications (1-2Gy), flexibility and easy analysis with a common desktop scanner.…”
Section: Introductionmentioning
confidence: 99%
“…Historically these have included MD-55 and HS film [6][7][8][9][10][11][12] , ISP's films designed specifically for radiotherapy applications where large doses (up to 30 Gy) are required, XR-R films [13][14][15] for high dose diagnostic imaging applications through to films such as XRQA [16][17] which is designed for low dose assessment at kilovoltage x-ray energies. Probably the most used film for radiation dosimetry in therapy applications has been Gafchromic EBT film [18][19][20][21][22][23][24] . Its properties have included lowest energy dependence of any film type dosimeter, radiation sensitivity matched to therapy applications (1-2Gy), flexibility and easy analysis with a common desktop scanner.…”
Section: Introductionmentioning
confidence: 99%
“…Dosimetric challenges from the nose contour have been recognized in the literature. Currie et al (2007) conducted a dosimetric study on a nose phantom using both single anterior field and laterally opposed approach [ 9 ]. In their study, there is a significant dose drop off from depth of 6.5 mm to 21.5 mm, from 84% to 50%, respectively [ 9 ].…”
Section: Discussionmentioning
confidence: 99%
“…However, treatment of such cancers of the face, particularly on the nose, can be challenging. Traditionally, nonmelanoma skin cancers in this location are treated with a single anterior field using ortho-Voltage or electron beam radiation [ 9 ]. However, delivering a homogeneous dose to the target can often be difficult due to the contour variability.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The low X-ray energy dependence of radiochromic films [1,2] make them clinically useful in both kilovoltage X-ray applications [3][4][5][6][7] and high energy X-ray applications [8][9][10][11]. Radiochromic films that are commonly used in these applications include Gafchromic EBT and EBT2 films.…”
Section: Introductionmentioning
confidence: 99%