2003
DOI: 10.1016/s0958-3947(02)00248-0
|View full text |Cite
|
Sign up to set email alerts
|

Verification techniques and dose distribution for computed tomographic planned supine craniospinal radiation therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2008
2008
2013
2013

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 6 publications
0
8
0
Order By: Relevance
“…An overdosage of up to 40% in consistently applied 5-mm overlap was found [17]. Dosimetry of supine treatment with a single extended distance spinal field revealed a dose range of 89.3-108% at the junction [3]. Without a daily check, a craniospinal junction error of 0.5 mm (± 5.4) underlap was reported.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…An overdosage of up to 40% in consistently applied 5-mm overlap was found [17]. Dosimetry of supine treatment with a single extended distance spinal field revealed a dose range of 89.3-108% at the junction [3]. Without a daily check, a craniospinal junction error of 0.5 mm (± 5.4) underlap was reported.…”
Section: Resultsmentioning
confidence: 99%
“…A well-established technique in prone position has been measured long time ago for dose inhomogeneities in detail [22]. Several reports with immobilization in supine position have been published [3,5,11,13,15,18]. Our idea was to enlarge SSD to get beam sizes capable of covering the whole spinal axis.…”
Section: Introductionmentioning
confidence: 99%
“…and spinal-spinal fields is a concern for supine positioning because visualization of the light field on the patient is no longer applicable. Chang et al 9) described 2 verification techniques for the supine position. Daily verification required placement of a wire over the patient's chin to mark the inferior border of the light field from the cranial field, followed by a PA portal image of the spinal field to verify the approximate gap at the craniospinal junction, which was planned at 0.3 cm separation.…”
Section: Verification Of the Field Junction Between Craniospinal Fieldsmentioning
confidence: 99%
“…Radiation therapy for patients with head and neck, [1][2][3] craniospinal, 4 and breast cancer 5 commonly use two separate abutting fields. Precise asymmetric jaw junctioning at the central axis of radiation field (half-beam block) is imperative to avoid treatment complications due to substantial overlapping or underlapping of the abutting fields.…”
Section: Introductionmentioning
confidence: 99%