Versatile Seebeck and electrical resistivity measurement setup for thin films

Abstract: A custom setup for Seebeck coefficient and electrical resistivity measurements of thin films as a function of temperature in the range of 10–300 K was developed. The Seebeck coefficient is measured using a two-probe arrangement and using either a dynamical or steady/quasi-steady differential method. The temperature differences (ΔTs) for these measurements across the samples are achieved by using resistive heaters embedded in two copper blocks. The sample is screwed to these blocks and is in pressured contact w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 36 publications
0
8
0
Order By: Relevance
“…The evaluation of the temperature dependence (20–325 K) of S and σ of the TE film was carried out following Ferreira‐Teixeira et al. [ 68 ] procedure.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The evaluation of the temperature dependence (20–325 K) of S and σ of the TE film was carried out following Ferreira‐Teixeira et al. [ 68 ] procedure.…”
Section: Methodsmentioning
confidence: 99%
“…Regarding the transport properties, the roomtemperature Seebeck coefficient was measured using an in-plane homemade setup composed of two independent Cu support pillars already reported in Pires et al [44] The room-temperature electrical conductivity of the printed thermoelectric film was measured using the four-point method where a 2410-C SourceMeter from Keithley Instruments Inc. was used. The evaluation of the temperature dependence (20-325 K) of S and 𝜎 of the TE film was carried out following Ferreira-Teixeira et al [68] procedure.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Electronic Transport Characterization. The resistivity was measured with standard four linear contacts geometry or by using the home developed setup described 57 in a closed cycle cryostat (APD Cryogenics, Inc. System, HC-4 MK1 compressor) with a temperature range [10−300] K. Magnetoconductance measurements were carried out with four linear contacts or in a van der Pauw geometry with magnetic field perpendicular to the thin film. The measurements were performed using a cryogen-free measurement system from Cryogenic Limited and in an AC mode at 23 Hz.…”
Section: ■ Methodsmentioning
confidence: 99%
“…The Seebeck coefficient measurement techniques are based on differential or integral method, and their differences are shown in table 1 [29,[42][43][44]. In the differential method, the steadystate method and the quasi-steady state method are suitable for the combination of resistivity measurement methods because the temperature of sample can be kept constant.…”
Section: Seebeck Coefficient Data Collectionmentioning
confidence: 99%