Vertical Nonlinear Temperature Gradient and Temperature Load Mode of Ballastless Track in China

Abstract: In the process of heat exchange with the external environment, the internal temperature of ballastless track structure presents a nonlinear distribution. The vertical temperature gradient will cause repeated warping and deformation of track slab, resulting in mortar layer separation, which will affect driving comfort and track durability. The traditional temperature field analysis method of concrete structure based on thermodynamics has the disadvantages of too many assumptions, difficult parameter selection a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(2 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…In addition to the temperature gradient, the overall temperature difference with the lower foundation is also formed during the temperature change in the track slab [19]. It is difficult to maintain a permanent bonding state between the bottom of the track slab and the mortar.…”
Section: Mortar Layer Under Track Slab With Poor Bondingmentioning
confidence: 99%
“…In addition to the temperature gradient, the overall temperature difference with the lower foundation is also formed during the temperature change in the track slab [19]. It is difficult to maintain a permanent bonding state between the bottom of the track slab and the mortar.…”
Section: Mortar Layer Under Track Slab With Poor Bondingmentioning
confidence: 99%
“…The maximum positive temperature gradient of the ballastless track in China occurs from 13:30 to 16:00 in May to August, and the average maximum vertical positive temperature difference is 17.0 • C. The maximum negative temperature gradient occurs from 5:00 to 5:30 in January, and the average maximum negative temperature difference is 8.7 • C. The surface temperature of the ballastless track in Chengdu, Changsha, and southeast coastal areas exceeds 45 • C in summer, and the lowest surface temperature of the track slab in Urumqi and Harbin is lower than −16 • C in winter. For central China, the vertical temperature gradient of the track slab is −2~10 • C [70,71].…”
Section: Complex Temperature Loadmentioning
confidence: 99%