2020
DOI: 10.7149/opa.53.4.51047
|View full text |Cite
|
Sign up to set email alerts
|

Visual acuity assessment in phakic and pseudophakic eyes under red, green, and blue illumination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
1
0
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 0 publications
1
1
0
2
Order By: Relevance
“…Although LCA was nearly eliminated by using G illumination, the visual benefit of solely suppressing LCA is unnoticeable in phakic human vision because monochromatic aberrations cause a larger reduction in visual quality [ 41 43 ]. This fact was formerly reported for monofocal pseudophakic subjects as well [ 44 ]. Evidence of spatio-chromatic changes in pseudophakic vision with diffractive IOLs are provided in this study.…”
Section: Discussionsupporting
confidence: 79%
“…Although LCA was nearly eliminated by using G illumination, the visual benefit of solely suppressing LCA is unnoticeable in phakic human vision because monochromatic aberrations cause a larger reduction in visual quality [ 41 43 ]. This fact was formerly reported for monofocal pseudophakic subjects as well [ 44 ]. Evidence of spatio-chromatic changes in pseudophakic vision with diffractive IOLs are provided in this study.…”
Section: Discussionsupporting
confidence: 79%
“…The stimulus size of successive lines followed decimal progression in steps of 0.1 decimal. Unlike the recommended logarithmic progression, this design permitted smaller increments in the stimulus size, thus allowing us to detect subtle VA variations [13]. These additional decimal acuity grades, permitted by ISO 8596 (2018) [12], are particularly necessary when assessing young healthy observers, who can generally reach high VA levels.…”
Section: Methodsmentioning
confidence: 99%
“…El análisis de resultados obtenidos con el resto de iluminaciones revela el impacto de un implante difractivo en la AV. En el foco de lejos, los tres grupos de pacientes muestran una AV asimétrica entre el iluminante R y el B: con luz R se alcanza mucho mejor AV que con luz B. Estos resultados son consistentes con los obtenidos en el estudio previo realizado con pacientes implantados con lente monofocal (Clavé et al, 2020), donde se observó la misma tendencia (capítulo 5, Tabla 5.3). A pesar de que la lente monofocal utilizada en aquel trabajo tenía un número de Abbe inferior al de las lentes trifocales difractivas (nº Abbemonofocal=47, nº Abbedifractivas=58), en ambos casos la lente intraocular no neutraliza el efecto de la ACL del ojo, haciendo que éste se comporte como un hipermétrope leve con luz R y como miope con luz B.…”
Section: Discussionunclassified
“…En el capítulo cinco, se ha comprobado la influencia de la ACL en la agudeza visual cromática (AV) en ojos fáquicos y pseudofáquicos monofocales y se han comparado estos valores de AV con los valores de diferencia cromática de refracción (CDRx) encontrados en la literatura (Vinas et al, 2015;Clavé et al, 2020). Los resultados obtenidos en este trabajo previo son consistentes con los valores de CDRx encontrados y nos confirman la validez del método empleado.…”
Section: Introducción Y Propósitounclassified