2015
DOI: 10.1039/c4ay03021d
|View full text |Cite
|
Sign up to set email alerts
|

Visual colorimetry for determination of trace arsenic in groundwater based on improved molybdenum blue spectrophotometry

Abstract: A sensitive on-site visual method for determination of trace arsenic in groundwater based on molybdenum blue colorimetry combined with a membrane filtration technique was developed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0
1

Year Published

2015
2015
2025
2025

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 29 publications
(21 citation statements)
references
References 37 publications
(37 reference statements)
0
17
0
1
Order By: Relevance
“…Recientemente, Okazaki et al (2015) informaron sobre un dispositivo portátil para la determinación de trazas de As en agua subterránea por colorimetría visual equipado con dos accesorios, un cartucho de CaCO 3 y un soporte de membrana impregnado con molibdeno; con dicho dispositivo se obtuvo un LD de 5 μg/L. La operación del dispositivo fue costosa debido al uso de un cartucho de CaCO 3 junto con filtros de membrana.…”
Section: Resultados Y Discusiónunclassified
“…Recientemente, Okazaki et al (2015) informaron sobre un dispositivo portátil para la determinación de trazas de As en agua subterránea por colorimetría visual equipado con dos accesorios, un cartucho de CaCO 3 y un soporte de membrana impregnado con molibdeno; con dicho dispositivo se obtuvo un LD de 5 μg/L. La operación del dispositivo fue costosa debido al uso de un cartucho de CaCO 3 junto con filtros de membrana.…”
Section: Resultados Y Discusiónunclassified
“…For DIC, a custom-built photographic box (6.1×6.1×7.7 inch) modified from previous design 22 was used to eliminate any effects of environmental light. Three replicates were done for each arsenic concentration by placing the tubes at sample holders inside a custom-built photographic box.…”
Section: Colorimetric Test Of Arsenic Using Bf 2 -Cur-film and Quantimentioning
confidence: 99%
“…The average intensities of red, green, and blue colors (RGB values) from 6 images of three replicates (18 values in total) at each arsenic concentration were investigated using a custom-built RGB analysis program. [21][22][23] Each average was used as a single data point to establish calibration curve.…”
Section: Colorimetric Test Of Arsenic Using Bf 2 -Cur-film and Quantimentioning
confidence: 99%
“…[7][8][9][10] This technique, which does not use harmful organic solvents, is suitable for on-site works. A direct comparison of the membrane filter colorations provided by the enrichment onto the filter surface enables highly sensitive determination of the target analyte, [11][12][13][14][15][16][17][18][19][20][21][22][23][24][25] and some methods are commercially available.…”
Section: Introductionmentioning
confidence: 99%