Background
The traditional audiovisual sexual stimulation (AVSS) test may experience limitations including low erectile response rate and lack of unified diagnostic criteria.
Aim
We aimed to explore the clinical value of AVSS with virtual reality (VR-AVSS) test in assessing erectile function and diagnosing erectile dysfunction (ED).
Methods
Participants 18 to 60 years of age were screened for analysis in 3 clinical centers from June 2020 to March 2022. Demographic data, 5-item International Index of Erectile Function (IIEF-5), erectile hardness score (EHS), and self-reported symptom questions were collected. The ED patients and control patients were confirmed according to the IIEF-5 and EHS. All subjects watched a 60-minute erotic video by VR device during RigiScan recording. The parameters including tip average rigidity, tip effective erectile duration (duration of rigidity ≥60%, tip effective erectile duration), base average rigidity, and base effective erectile duration were evaluated.
Outcomes
The main outcome of interest was the application of VR immersion technology to improve the traditional AVSS test.
Results
A total of 301 ED cases and 100 eligible control patients were included for final analysis. Compared with control patients, ED cases had significantly lower IIEF-5 scores, EHS, positive response rate, and erectile rigidity and duration. The positive response rate of ED and control patients were 75.5% and 90.9%, respectively. The cutoff points of tip average rigidity, tip effective erectile duration, base average rigidity, and base effective erectile duration were 40.5% (sensitivity: 77.6%, specificity: 70.2%; P < .001), 4.75 minutes (sensitivity: 75.9%, specificity: 75.4%; P < .001), 48.5% (sensitivity: 77.6%, specificity: 75.1%; P < .001), and 7.75 minutes (sensitivity: 79.3%, specificity: 75.7%; P < .001).
Clinical Implications
The technological superiority of VR will enable the VR-AVSS immersion test to be a more accurate detection than traditional AVSS modes.
Strengths and Limitations
Our study applied VR immersion technology to establish the standard operation procedure for the AVSS test, which could effectively reduce the interference of adverse factors and minimize the detecting errors. However, the test data only included positive response subjects, so the true erectile status of men with a negative response to the AVSS test cannot be obtained.
Conclusions
The VR-AVSS test can effectively improve the diagnostic accuracy of ED. The average rigidity and effective erectile duration were the optimal diagnostic parameters for excluding ED.