Abstract: Abnormal ECGs were more than twice as common after computer-based than after visual measurements. Such a difference will markedly influence the number of athletes who need further examinations. Reference values may need adjustments dependent on measurement methods.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0
2

Year Published

2014
2014
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(14 citation statements)
references
References 21 publications
0
12
0
2
Order By: Relevance
“…Secondly we examined it dichotomously at the highest amount of stress compared to the two lower tertiles. Cohen’s Kappa was used to assess inter-scale agreement on perceived stress in tertiles and dichotomously (32, 33). Due to the nonparametric distribution of the data, the Spearman’s rank correlation was used to assess the correlation between the scores of the Assessment of Partner/Other Support and Self Esteem scales from the PPP were tested with the total scores of the PSS and Perceived Stress score of the PPP.…”
Section: Discussionmentioning
confidence: 99%
“…Secondly we examined it dichotomously at the highest amount of stress compared to the two lower tertiles. Cohen’s Kappa was used to assess inter-scale agreement on perceived stress in tertiles and dichotomously (32, 33). Due to the nonparametric distribution of the data, the Spearman’s rank correlation was used to assess the correlation between the scores of the Assessment of Partner/Other Support and Self Esteem scales from the PPP were tested with the total scores of the PSS and Perceived Stress score of the PPP.…”
Section: Discussionmentioning
confidence: 99%
“…In our study all digital samples were displayed, and the on‐screen calipers measured durations and amplitudes down to 2 ms and 0.05 mV, respectively. Hence, small deflections as T‐wave inversions ≥ 1.0 mm and Q waves ≥ 3.0 mm were easier to detect (Berge et al., ). Third, the visual assessment both on paper and on‐screen has subjective components: where to start and end a measurement and in choice of lead.…”
Section: Discussionmentioning
confidence: 99%
“…In our study all digital samples were displayed, and the on-screen calipers measured durations and amplitudes down to 2 ms and 0.05 mV, respectively. Hence, small deflections as T-wave inversions ≥ 1.0 mm and Q waves ≥ 3.0 mm were easier to detect (Berge et al, 2014).…”
Section: Ecg Findings According To the Esc And Seattle Criteriamentioning
confidence: 98%
“…Damit lassen sich sportbedingte EKG-Veränderungen zuverläs-siger erfassen und besser von pathologischen Veränderungen abgrenzen [18,21]. So werden falsch-positive und falsch-negative Befunde deutlich geringer, der prä-diktive Wert des Ruhe-EKG wird erheblich gesteigert [3,4]. Zusätzlich erweist sich die Software-gesteuerte EKG-Analyse anhand der Seattle-Kriterien mit einem entsprechenden EKG-Gerät als genauer (richtiger und präziser; [1, 18,24]) als die visuelle Interpretation [3,4,14].…”
Section: Zuverlässigkeit Der Befundungunclassified
“…So werden falsch-positive und falsch-negative Befunde deutlich geringer, der prä-diktive Wert des Ruhe-EKG wird erheblich gesteigert [3,4]. Zusätzlich erweist sich die Software-gesteuerte EKG-Analyse anhand der Seattle-Kriterien mit einem entsprechenden EKG-Gerät als genauer (richtiger und präziser; [1, 18,24]) als die visuelle Interpretation [3,4,14]. Für den weniger erfahrenen Arzt wird damit die EKG-Beurteilung beim Sportler erleichtert, ersetzt aber nicht die Schulung in Sport-EKG und Sportkardiologie.…”
Section: Zuverlässigkeit Der Befundungunclassified