2014
DOI: 10.1253/circj.cj-14-0754
|View full text |Cite
|
Sign up to set email alerts
|

Visualization of Pulmonary Vein-Left Atrium Reconduction Site on Delayed-Enhancement Magnetic Resonance Imaging in the Second Atrial Fibrillation Catheter Ablation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
5

Relationship

5
0

Authors

Journals

citations
Cited by 12 publications
(17 citation statements)
references
References 7 publications
0
16
0
1
Order By: Relevance
“…This scan technique has been established, and the acquired images were used for the AF ablation procedure . First, contrast‐enhancement magnetic resonance angiography (CE‐MRA) of the PV‐LA anatomy was acquired with a breath‐hold 3D fast field echo (FFE) sequence in the coronal plane during the first pass of a contrast agent (gadobutrol, Gadovist; Bayer Yakuhin, Osaka, Japan) injection at a dose of 0.1 mmol/kg . The purpose of the scanning in the coronal plane is to reduce the number of acquisition slices and shorten the breath‐holding time.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This scan technique has been established, and the acquired images were used for the AF ablation procedure . First, contrast‐enhancement magnetic resonance angiography (CE‐MRA) of the PV‐LA anatomy was acquired with a breath‐hold 3D fast field echo (FFE) sequence in the coronal plane during the first pass of a contrast agent (gadobutrol, Gadovist; Bayer Yakuhin, Osaka, Japan) injection at a dose of 0.1 mmol/kg . The purpose of the scanning in the coronal plane is to reduce the number of acquisition slices and shorten the breath‐holding time.…”
Section: Methodsmentioning
confidence: 99%
“…9 First, contrast-enhancement magnetic resonance angiography (CE-MRA) of the PV-LA anatomy was acquired with a breath-hold 3D fast field echo (FFE) sequence in the coronal plane during the first pass of a contrast agent (gadobutrol, Gadovist; Bayer Yakuhin, Osaka, Japan) injection at a dose of 0.1 mmol/kg. 10 The purpose of the scanning in the coronal plane is to reduce the number of acquisition slices and shorten the breath-holding time. Then the LGE-MRI of the LA with the PVs was acquired using a 3D inversion recovery, respiration navigated, electrocardiogram-gated, T1-FFE sequence in the transverse plane 15 minutes after the contrast injection, which has been previously reported.…”
Section: Mri Acquisitionmentioning
confidence: 99%
“…This scan technique has been established, and acquired images have been used for the AF ablation procedure . First, contrast enhancement–magnetic resonance angiography (CE‐MRA) of the PV–LA anatomy was acquired with a breath‐hold 3D fast field echo (FFE) sequence in the coronal plane during the first pass of a contrast agent (gadobutrol, Gadovist; Bayer Yakuhin, Osaka, Japan) injection at a dose of 0.1 mmol/kg . Then, the LGE‐MRI of the LA with PVs was acquired using a 3D inversion recovery, respiration‐navigated, electrocardiogram‐gated, T1‐FFE sequence in the transverse plane 15 min after a contrast injection, which have been previously reported .…”
Section: Methodsmentioning
confidence: 99%
“…A 3D visualization and segmentation of the MRI were performed with AZE Virtual Place (AZE Virtual Place; AZE, Tokyo, Japan). The method for the 3D visualization has been reported previously [3,12,13]. Briefly, we segmented the LA wall and calculated the mean value and standard deviation (SD) of the pixel intensity histogram.…”
Section: Methodsmentioning
confidence: 99%