The structure and behavior of rotating stall cell were experimentally clarified in a diagonal flow fan. The specific-speed of the fan was 1140 (r/min, m 3 /min, m), and the total pressure-rise coefficient at design flow-rate was 0.345. The static pressure on outer casing wall and the total pressure at rotor inlet and outlet were measured using a high response pressure transducer. The measured data were processed by the use of DPLA technique, and the structure and behavior of rotating stall cell were obtained. As a result, the stall cell extent for circumferential and spanwise direction and the pressure distributions inside stall cell were clarified. The details of stall cell propagation were also shown. K eywords: diagonal flow fan, rotating stall cell, unsteady flow, DPLA technique. CLC number: TH432.2 Document code: A