2018
DOI: 10.1016/j.clinph.2018.06.030
|View full text |Cite
|
Sign up to set email alerts
|

Visually validated semi-automatic high-frequency oscillation detection aides the delineation of epileptogenic regions during intra-operative electrocorticography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
77
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
5
3
2

Relationship

1
9

Authors

Journals

citations
Cited by 48 publications
(80 citation statements)
references
References 22 publications
3
77
0
Order By: Relevance
“…Importantly, it has been suggested, that pre-surgically assessed HFO rates might not be key in predicting seizure outcome, but that high rates recorded after resection might be an indicator of seizure reoccurrence (5054), suggesting the importance to disconnect HFO generating networks (53). Accordingly, Weiss et al (55) found that areas with fast ripples occurring on spikes that were not resected during epilepsy surgery were linked to a poor surgical outcome. This might also explain the high specificities occasionally reported by some studies (42, 50, 52, 56).…”
Section: High-frequency Oscillations In the Intracranial Eegmentioning
confidence: 99%
“…Importantly, it has been suggested, that pre-surgically assessed HFO rates might not be key in predicting seizure outcome, but that high rates recorded after resection might be an indicator of seizure reoccurrence (5054), suggesting the importance to disconnect HFO generating networks (53). Accordingly, Weiss et al (55) found that areas with fast ripples occurring on spikes that were not resected during epilepsy surgery were linked to a poor surgical outcome. This might also explain the high specificities occasionally reported by some studies (42, 50, 52, 56).…”
Section: High-frequency Oscillations In the Intracranial Eegmentioning
confidence: 99%
“…The lack of specificity of spikes, as the irritative zone is usually broader than the SOZ, and the presence of high rates of physiological HFOs weakened their respective performance. In fact, HFOs and spikes are rather complementary because merging the two markers does outperform all other markers at both predicting the SOZ [20] and the outcome [25,26]. Unfortunately, the predictive performance was quite low for some patients (Fig.…”
Section: High-frequency Os-cillations and Spikes Are Complementarymentioning
confidence: 97%
“…Recently, a semi-automatic method has been evaluated to identify epochs with high frequency oscillatory (HFO) activity, a characteristic of epileptic EEG and iEEG Shimamoto et al, 2018;Weiss et al, 2018). The algorithm, run only on depth electrodes for optimal signal-to-noise, annotates an epoch with one of the following labels that are then visually validated: 0) No HFO event detected, 1) Ripple superimposed in an interictal discharge, 2) Sharply contoured epileptiform spike, 3) Ripple on oscillation, 4) Fast ripple superimposed in an interictal discharge, 5) Fast ripple on oscillation.…”
Section: Neurologist-based Epoch Exclusionmentioning
confidence: 99%