1995
DOI: 10.1016/0003-2670(95)00217-n
|View full text |Cite
|
Sign up to set email alerts
|

Vitamin B1 ion-selective microelectrode based on a liquid-liquid interface at the tip of a micropipette

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

1999
1999
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(9 citation statements)
references
References 21 publications
0
9
0
Order By: Relevance
“…Beni et al [104] showed that electrodeposition of the Se onto the Au electrodes resulted in the irreversible formation of the SeAu alloy limiting the use of the micro-electrode arrays in time. [87,111], propranolol [91], neurotransmitters such as acetylcholine [88] and choline [89], heavy metals such as Cd 2+ [112], Vitamin B1 [113] and polysaccharide such as heparin [114]. Most of the species detected by stripping analysis are cationic and hence ASV is the most commonly used method.…”
Section: Ii4 Optimation Of the Analytical Performances Of Micro-intmentioning
confidence: 99%
“…Beni et al [104] showed that electrodeposition of the Se onto the Au electrodes resulted in the irreversible formation of the SeAu alloy limiting the use of the micro-electrode arrays in time. [87,111], propranolol [91], neurotransmitters such as acetylcholine [88] and choline [89], heavy metals such as Cd 2+ [112], Vitamin B1 [113] and polysaccharide such as heparin [114]. Most of the species detected by stripping analysis are cationic and hence ASV is the most commonly used method.…”
Section: Ii4 Optimation Of the Analytical Performances Of Micro-intmentioning
confidence: 99%
“…In ITSV, an aqueous analyte ion is potentiostatically preconcentrated into a water-immiscible organic phase and then voltammetrically stripped to yield an enhanced current response. ITSV was successfully applied for relatively lipophilic ions such as acetylcholine [120, 121], vitamin B1 [122], various protonated amines [123], tetraalkylammoniums [124126], anionic surfactants [126, 127], and β -blocker propranolol [128, 129]. In addition, various ionophores were employed to enable ITSV of highly hydrophilic ions such as alkaline earth metal ions [130] and oligopeptides [131].…”
Section: It Stripping Voltammetry For Trace Analysismentioning
confidence: 99%
“…The preconcentration effect appears promising for determination of ions at very low concentration levels. Using a similar technique, Huang et al determined vitamin B 1 down to 4.6610 À6 M in aqueous solution with a linear range of 5610 À5 to 1610 À3 M [37]. Theoretically, the detection limit of stripping analysis is determined by the ratio of the volumes of the outer solution and the ®lling solution inside the pipette, and this technique is potentially useful for measurements of very low ( 1 nM) concentrations.…”
Section: Micro-ities As Sensorsmentioning
confidence: 99%