Volatile Constituents and Anti-Osteoporotic Activity of the n-Hexane Extract From Homalomena gigantea Rhizome

Abstract: This study analyzed the chemical composition and anti-osteoporosis activity of the n-hexane extract of Homalomena gigantea rhizome. Sixty compounds, representing 92.0% of the extract, were identified by gas chromatography-mass spectrometry. Linalool (15.3%), oplopanone (9.8%), ( Ε)-α-atlantone (5.6%), khusinol acetate (5.4%), bullatantriol (4.3%), and β-sitosterol (3.8%) were the main constituents. The anti-osteoporotic activity of the n-hexane extract was determined by measuring alkaline phosphatase (ALP) act… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 42 publications
0
4
0
Order By: Relevance
“…The GC-MS analysis was conducted using a Shimadzu Technologies GCMS-QP2010 Plus chromatograph (Shimadzu, Kyoto, Japan), equipped with a fused silica Equity-5 capillary column (30 m × 0.25 mm, film thickness 0.25 µm, Supelco, Bellefonte, PA, USA) [ 38 , 39 , 40 , 41 ]. The analytical parameters were set as follows: helium was utilized as the carrier gas at a flow rate of 1.2 mL/min, while the injector and interface temperatures were maintained at 280 °C.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The GC-MS analysis was conducted using a Shimadzu Technologies GCMS-QP2010 Plus chromatograph (Shimadzu, Kyoto, Japan), equipped with a fused silica Equity-5 capillary column (30 m × 0.25 mm, film thickness 0.25 µm, Supelco, Bellefonte, PA, USA) [ 38 , 39 , 40 , 41 ]. The analytical parameters were set as follows: helium was utilized as the carrier gas at a flow rate of 1.2 mL/min, while the injector and interface temperatures were maintained at 280 °C.…”
Section: Methodsmentioning
confidence: 99%
“…The GC-MS analysis was conducted using a Shimadzu Technologies GCMS-QP2010 Plus chromatograph (Shimadzu, Kyoto, Japan), equipped with a fused silica Equity-5 capillary column (30 m × 0.25 mm, film thickness 0.25 µm, Supelco, Bellefonte, PA, USA) [38][39][40][41]. The analytical parameters were set as follows: helium was utilized as the carrier gas at a flow rate of 1.2 mL/min, while the injector and interface temperatures were maintained at 280 • C. The temperature program entailed a ramp from 60 • C (held for 3 min) to 240 • C (held for 15 min) at a rate of 3 • C/min, followed by a final ramp to 280 • C (held for 35 min) at a rate of 5 • C/min for the column.…”
Section: Gc-ms Analysismentioning
confidence: 99%
“…The compounds were determined by comparing their mass spectra with those in Wiley 7 and NIST 11 libraries from the GC-MS system, as well as relevant literature data. Data quantification of the constituents was determined by the relative peak area [24].…”
Section: Determination Of the Volatile Constituentsmentioning
confidence: 99%
“…The GC-MS analysis was conducted using a Shimadzu Technologies GCMS-QP2010 Plus chromatograph (Shimadzu, Kyoto, Japan) equipped with a fused silica Equity-5 capillary column (30 m × 0.25 mm, film thickness 0.25 µm, Supelco). 26,27,28,29 The analytical parameters were set as follows: Helium was used as the carrier gas at a flow rate of 1.5 mL/min, with injector and interface temperatures set at 280 °C. The temperature program involved a ramp from 60 °C (held for 2 min) to 240 °C (held for 10 min) at a rate of 3 °C/min, followed by a final ramp to 280 °C (held for 40 min) at a rate of 5 °C/min for the column.…”
Section: Distillationmentioning