2018 IEEE 2nd International Conference on Dielectrics (ICD) 2018
DOI: 10.1109/icd.2018.8514776
|View full text |Cite
|
Sign up to set email alerts
|

Voltage Distribution in the Stator Windings of High Voltage Motors Fed by PWM Drives Part I: Effects of the Pulse Characteristics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…The experiment results on a real prototype are in high accordance with that of simulation. Moghadam conducts experiments on interturn voltage within a single coil of a motor under different electrical parameters [16]. The author finds that besides shorter rise time, the longer pulse width can also bring a stronger interturn voltage drop, leading to a more serious electrical stress on the coil's insulation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The experiment results on a real prototype are in high accordance with that of simulation. Moghadam conducts experiments on interturn voltage within a single coil of a motor under different electrical parameters [16]. The author finds that besides shorter rise time, the longer pulse width can also bring a stronger interturn voltage drop, leading to a more serious electrical stress on the coil's insulation.…”
Section: Introductionmentioning
confidence: 99%
“…[ [13][14][15][16] • Reveal the interturn and inter-coil overvoltage within the winding of inverter-fed motors.…”
mentioning
confidence: 99%
“…With these stray parameters, electric circuit model can be built in software for circuit analysis, which enables the simulation of the waveform for interturn voltage drop in time domain [12,[59][60]. For some of the HV motor, the dimension of the winding is large enough that a probe can be used for directly testing the inter-layer or inter-winding section voltage drop [61][62]. The results of these papers show that if pulse voltage is added to the winding, inter-turn overvoltage exists, and this overvoltage would be highest between turns closest to the winding terminals.…”
Section: Project Motivationsmentioning
confidence: 99%
“…Unlike the PD and endurance tests on the samples such as insulation film or electromagnet wires, the transformer's winding structure is not the same as that of the motor. Therefore, the conclusions from [12,[59][60][61][62] cannot be directly applied in the field of medium frequency transformer. Similar studies focusing on the electric stress suffered by MVMF transformer's winding in transient time domain is necessary.…”
Section: Project Motivationsmentioning
confidence: 99%