Voltage prevention and emergency coordinated control strategy for photovoltaic power plants considering reactive power allocation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“… Test 3: Fixed irradiance commanding constant active power pump to grid, Volt-VAR operation Here the irradiance is kept fixed at 500 W m 2 ⁄ . During the time period, 0 < t < 1 and 3 < t < 5 when the grid voltage (in per unit) is between U 1 and U 2 values of characteristic curve of figure 5, the inverter operates at unity power factor with zero reactive power [25]. During the time period, 1 < t < 2, when the gird voltage is below U low (refer characteristic curve), reactive capacitive power injected into the grid (positive value set).…”
Section: Three-phase Grid-linked Inverter Controller Systemmentioning
confidence: 99%
“… Test 3: Fixed irradiance commanding constant active power pump to grid, Volt-VAR operation Here the irradiance is kept fixed at 500 W m 2 ⁄ . During the time period, 0 < t < 1 and 3 < t < 5 when the grid voltage (in per unit) is between U 1 and U 2 values of characteristic curve of figure 5, the inverter operates at unity power factor with zero reactive power [25]. During the time period, 1 < t < 2, when the gird voltage is below U low (refer characteristic curve), reactive capacitive power injected into the grid (positive value set).…”
Section: Three-phase Grid-linked Inverter Controller Systemmentioning
confidence: 99%
“…Because the VDAPF is capable of reactive power compensation in addition to harmonic mitigation, the dominant nodes determined based on the harmonic index from ( 9) and the integrated sensitivity index from (10) are used as the candidate nodes for VDAPFs, as shown in (11). The dominant nodes determined based on the reactive power index from ( 12) are used as the candidates for SVGs.…”
Section: Selection Of Dominant Nodes As Candidatesmentioning
confidence: 99%
“…There are much Var equipment for voltage problem, including on-load tap changers, shunt capacitors, static var compensators and static var generators (SVGs). Among them, SVG has great characteristics of outputting capacitive or inductive reactive power smoothly and reacting to instructions rapidly, so it is widely used [9,10]. The harmonic level of the network can be controlled by installing filters directly on the customer side in the traditional DNs where harmonic disturbance sources are fewer and generally concentrated in some special customers IET Gener.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3][4] The return on investment of PV systems has increased as a consequence of the PV panels and their associated components price reduction. 5,6 New PV technologies have emerged regarding materials like multi-crystalline…”
mentioning
confidence: 99%