2020
DOI: 10.1109/tie.2019.2949526
|View full text |Cite
|
Sign up to set email alerts
|

Voltage-Source Converter Energy Efficiency Classification in Accordance With IEC 61800-9-2

Abstract: New global energy efficiency classification standard IEC 61800-9-2 for frequency converters and motor systems has been recently launched. It classifies the energy efficiency of the converters and motor-drive systems and introduces three different methods to determine a voltage source converter (VSC) losses for the classification. In here, experimental tests are carried out using the input-output method and the calorimetric method to determine the losses and efficiency of a 160 kW commercial voltage source conv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 28 publications
0
4
0
1
Order By: Relevance
“…The option to apply typical fixed and variable speed general-purpose drive duty cycles, as has been conducted in many previous studies [20,21], is also very interesting. Still, we have decided to leave it open since the existing possibilities at the level of industrial applications are very diverse.…”
Section: Energy Savingmentioning
confidence: 99%
“…The option to apply typical fixed and variable speed general-purpose drive duty cycles, as has been conducted in many previous studies [20,21], is also very interesting. Still, we have decided to leave it open since the existing possibilities at the level of industrial applications are very diverse.…”
Section: Energy Savingmentioning
confidence: 99%
“…Norma IEC 61 800-9-2 definiuje metody pomiarowe, wymagania oraz trzy klasy sprawności energetycznej IE0, IE1 oraz IE2. Sprawność dobranego przemiennika ACS880-01-02A4-3+E202+L517 spełnia wymagania najwyższej klasy sprawności energetycznej IE2 [16], [17]. Sprawność przemiennika dla obciążenia znamionowego i prędkości wirnika na poziomie 45Hz wynosi ηf = 0,965 [18].…”
Section: Sprawnośćunclassified
“…They allow motor soft-starting capabilities, accurate torque, speed and position controls with motor operations even at partial load maintaining reasonable energy-saving benefits [2]. The main drawback is correlated to the pulse-width-modulated voltage waveforms that generate high-frequency harmonics on both voltage and currents, causing significant additional power losses with respect to sinusoidal supply, which reduces motor efficiency, producing noise, vibrations and heat [3]- [4]. In this scenario, industrial and academic researchers pushed their efforts towards the optimization of electric drives performances by reducing the motor power losses both with hardware and software solutions [5]- [8].…”
Section: Introductionmentioning
confidence: 99%