2007
DOI: 10.1016/j.talanta.2006.09.031
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric determination of Cu(II) in natural waters and human hair at a meso-2,3-dimercaptosuccinic acid self-assembled gold electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
41
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 116 publications
(47 citation statements)
references
References 24 publications
4
41
0
Order By: Relevance
“…As presented in Table 2, the concentration of Cu in human hair sample obtained in the present procedure (12.53 μg g -1 ) is in the same range as the levels of Sabermahani et al (11.59 μg g -1 ), 14 Mohadesi et al (12.41 μg g -1 ), 15 Ramakrishna et al (13.90 μg g -1 ), 28 Bertazzo et al (14.89 -15.29 μg g -1 ) 29 and Rao et al (4.90 -22.54 μg g -1 ) 30 reported. Also, the results show the presence of Cu(II) in natural water samples.…”
Section: Analytical Applicationssupporting
confidence: 80%
See 2 more Smart Citations
“…As presented in Table 2, the concentration of Cu in human hair sample obtained in the present procedure (12.53 μg g -1 ) is in the same range as the levels of Sabermahani et al (11.59 μg g -1 ), 14 Mohadesi et al (12.41 μg g -1 ), 15 Ramakrishna et al (13.90 μg g -1 ), 28 Bertazzo et al (14.89 -15.29 μg g -1 ) 29 and Rao et al (4.90 -22.54 μg g -1 ) 30 reported. Also, the results show the presence of Cu(II) in natural water samples.…”
Section: Analytical Applicationssupporting
confidence: 80%
“…14,15 The hair sample was rinsed with acetone, and 4.20 g of dried sample was accurately weighted and burned in a furnace at 700˚C until a white powder was obtained. The obtained ash was dissolved in a minimum volume of concentrated nitric acid with heating.…”
Section: Pretreatment Of Real Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…For comparison, the performances of L-cysteine/ AuNPs-RGO/GCE and reported electrochemical electrodes [35][36][37][38][39] for Cu 2 + were summarized in Table 1. The Lcysteine/AuNPs-RGO/GCE showed high sensitivity and low LOD for the determination of Cu 2 + .…”
Section: Analytical Performance Of L-cysteine/aunps-rgo/gcementioning
confidence: 99%
“…[8][9][10][11][12][13][14] The present investigation was prompted by a desire to develop an alternative method for determination of bismuth based on adsorptive accumulation stripping voltammetry. The present scheme, based on the accumulation and reduction of bismuth-XO complex, offers both sensitivity and selectivity, and represents an attractive alternative to conventional stripping measurements of bismuth.…”
mentioning
confidence: 99%