2019
DOI: 10.1002/elan.201900278
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric Label‐free Detection of DNA Hypermethylation Using Polypyrrole‐modified Microelectrode Array

Abstract: An alternative strategy for the label‐free electrochemical detection of DNA hypermethylation using a microelectrode array as an oligodinucleotide (ODN) detector is presented. It relies on the oligonucleotide dependent electrostatic affinity interaction firstly with unmethylated ODN and then follow‐up with methylated DNA. The methylated cytosine status is quantified by monitoring the relative change in the exchange current at the ODN‐detector before and after the bisulfite treated DNA samples. This novel aproac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 33 publications
0
6
0
Order By: Relevance
“…The detection was carried out by differential pulse voltammetry (DPV) at clinically relevant concentrations (pg/mL) [ 67 ]. Other examples of micro- and nano-sized immunobiosensors have been reported for the detection of prostate-specific antigen (PSA) as a prostate carcinoma biomarker [ 26 ] and methylated DNA as a target for early tumor diagnosis and monitoring [ 68 ]. A microfluidic biosensor chip including Ag/AgCl and Au electrodes as RE and CE, respectively, and a Au nanoelectrodes array functionalized with a biosensor complex enabled the voltammetric determination of PSA with fM detection limit in nL volumes using a competitive immunoassay method [ 26 ].…”
Section: Micro- and Nano-sized Amperometric Sensorsmentioning
confidence: 99%
“…The detection was carried out by differential pulse voltammetry (DPV) at clinically relevant concentrations (pg/mL) [ 67 ]. Other examples of micro- and nano-sized immunobiosensors have been reported for the detection of prostate-specific antigen (PSA) as a prostate carcinoma biomarker [ 26 ] and methylated DNA as a target for early tumor diagnosis and monitoring [ 68 ]. A microfluidic biosensor chip including Ag/AgCl and Au electrodes as RE and CE, respectively, and a Au nanoelectrodes array functionalized with a biosensor complex enabled the voltammetric determination of PSA with fM detection limit in nL volumes using a competitive immunoassay method [ 26 ].…”
Section: Micro- and Nano-sized Amperometric Sensorsmentioning
confidence: 99%
“…This biosensor presented specificity and reproducibility, with low detection limits, as well as being disposable and regenerable. More recently, a label‐free voltametric assay was also developed [75]. The biosensor used a 16‐channel platinum microelectrode array chip.…”
Section: Biosensors For the Detection And Quantification Of Gstsmentioning
confidence: 99%
“…Indeed, under the prostatic carcinoma setting, GSTP1‐1 expression is silenced due to aberrant hypermethylation in its gene promoter. Different sensitive biosensors were developed and used for the determination of GSTP1‐1 hypermethylation as a prostate cancer biomarker [73–75].…”
Section: Biosensors For the Detection And Quantification Of Gstsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is effectively used in the fields of environmental electrochemistry, organic chemistry, inorganic chemistry and biochemistry. The effectiveness of CV results from its capability of rapidly observing the redox behavior over a wide potential range [24,25].…”
Section: Electrochemical Techniques For Afs Detectionmentioning
confidence: 99%