2020
DOI: 10.1016/j.jpba.2020.113422
|View full text |Cite
|
Sign up to set email alerts
|

Volumetric Absorptive Microsampling (VAMS) for assaying immunosuppressants from venous whole blood by LC–MS/MS using a novel atmospheric pressure ionization probe (UniSpray™)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
58
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 35 publications
(58 citation statements)
references
References 26 publications
0
58
0
Order By: Relevance
“…The disadvantage of TDM based on plasma samples is represented by the discomfort caused to patients to obtain venous samples by using sampling procedures that cannot be applied at all to pediatrics patients and/or newborns, limiting the widespread of TDM in such population. To overcome these issue, new microsampling devices are described in literature [34][35][36]. These systems allow to collect a known volume of blood by means of microfluidic system, nullifying the HCT and drop volume effects on the analytes determination [17,[19][20][21].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The disadvantage of TDM based on plasma samples is represented by the discomfort caused to patients to obtain venous samples by using sampling procedures that cannot be applied at all to pediatrics patients and/or newborns, limiting the widespread of TDM in such population. To overcome these issue, new microsampling devices are described in literature [34][35][36]. These systems allow to collect a known volume of blood by means of microfluidic system, nullifying the HCT and drop volume effects on the analytes determination [17,[19][20][21].…”
Section: Discussionmentioning
confidence: 99%
“…These systems allow to collect a known volume of blood by means of microfluidic system, nullifying the HCT and drop volume effects on the analytes determination [ 17 , 19 , 20 , 21 ]. Herein, we describe a new microsampling method for the simultaneous determination of THC and CBD using VAMS which has been demonstrated useful for the quantitative measurement of several drugs from venous and capillary blood including first-generation and third-generation antiseizure drugs [ 23 , 37 ], antibiotics [ 22 ] and immunosuppressants [ 35 , 36 , 37 ].…”
Section: Discussionmentioning
confidence: 99%
“…Several developments are being made to overcome the volume‐based bias leading to various novel techniques like Hemaxis, 37 hemaPEN, 38 Capitainer‐B, 39 Volumetric Absorptive Microsampling (VAMS)‐Mitra samplers, 40 Volumetric Absorptive Paper Disc (VAPD) and mini‐disc (VAPDmini), 41 Solid‐Phase Microextraction (SPME), 42 Fluispotter 43 and Tasso‐device 44 . The challenges are being eliminated, and precise analytical results are being obtained with innovative detection techniques 45–48 . Volumetrically derived dried blood microsampling continues to be a choice as it offers additional advantages of simplified logistics, preservation and transportation of samples.…”
Section: Microsamplingmentioning
confidence: 99%
“…44 The challenges are being eliminated, and precise analytical results are being obtained with innovative detection techniques. [45][46][47][48] Volumetrically derived dried blood microsampling continues to be a choice as it offers additional advantages of simplified 54 Another study demonstrated the application of DBS for the measurement of measles antibodies and vitamin A levels. The study was conducted by collecting DBS samples from 3316 individuals of age group between 0 and 49 years were collected for analysis of measles antibody.…”
Section: Microsamplingmentioning
confidence: 99%
See 1 more Smart Citation