Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

10
121
4
2

Year Published

2011
2011
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 185 publications
(137 citation statements)
references
References 24 publications
10
121
4
2
Order By: Relevance
“…The delivery time was equal to 4.6±0.7 min per dual arc and was considerably less than the 7F‐IMRT delivery time. Studies on other VMAT approaches based on double RapidArc approaches ( 8 , 51 , 52 ) have shown delivery times ranging from 2.6 to 3.9 min that are faster than our results, whilst other improved IMAT approaches ( 53 , 54 ) have displayed delivery times ranging from 6.3 to 14 min for conventional linac‐based techniques. Here, we did not determine the fastest method, as previous reports were not performed under the same measurement conditions.…”
Section: Discussioncontrasting
confidence: 66%
See 2 more Smart Citations
“…The delivery time was equal to 4.6±0.7 min per dual arc and was considerably less than the 7F‐IMRT delivery time. Studies on other VMAT approaches based on double RapidArc approaches ( 8 , 51 , 52 ) have shown delivery times ranging from 2.6 to 3.9 min that are faster than our results, whilst other improved IMAT approaches ( 53 , 54 ) have displayed delivery times ranging from 6.3 to 14 min for conventional linac‐based techniques. Here, we did not determine the fastest method, as previous reports were not performed under the same measurement conditions.…”
Section: Discussioncontrasting
confidence: 66%
“…Here, we did not determine the fastest method, as previous reports were not performed under the same measurement conditions. (Note: a faster RapidArc measurement (2.6 min) was performed by Clivio et al ( 8 ) ) Plans were optimized selecting a maximum dose rate of 600 MU/min with constant gantry speed rotating at the maximum speed allowed (5.5°/s) with a total of 177 CPs per arc, couch angle set to 0° and collimator set to either 30° or 36° (360°Xforthesecondarc), and managed all motions remotely in the reconfiguration state of the linac. VMAT plans created by the RapidArc algorithm can only be performed by the Varian machines.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…

Conformity index (CI): (11) defined as the ratio between the volume covered by the prescribed isodose and target volume. For test cases prostate, head‐and‐neck, C‐shape, and Multi Target, prescription dose are 75.6 Gy, 50.4 Gy, 50 Gy and 50 Gy, respectively.

Homogeneity index (HI): (5) defined as the dose difference normalized to dose prescription false(Dpresfalse) between doses covering 5% (D5) and 95% (D95) of the PTV.
…”
Section: Methodsmentioning
confidence: 99%
“…Homogeneity index (HI): (5) defined as the dose difference normalized to dose prescription false(Dpresfalse) between doses covering 5% (D5) and 95% (D95) of the PTV.…”
Section: Methodsmentioning