Wall Shear-Rate Estimation Within the 50cc Penn State Artificial Heart Using Particle Image Velocimetry

Abstract: Particle image velocimetry (PIV) has been gaining acceptance as a routine tool to evaluate the flow fields associated with fluid mechanical devices. We have developed algorithms to investigate the wall shear-rates within the 50cc Penn State artificial heart using low magnification, conventional particle image velocimetry (PIV). Wall shear has been implicated in clot formation, a major post-implant problem with artificial hearts. To address the issues of wall scattering and incomplete measurement volumes, assoc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
53
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
4
4
1

Relationship

1
8

Authors

Journals

citations
Cited by 73 publications
(55 citation statements)
references
References 30 publications
2
53
0
Order By: Relevance
“…Recently, particle image velocimetry (PIV) has become a powerful tool for quantitative measurement of flow velocities in bioengineering field, such as flows around the artificial heart and valve (30) - (32) . As an application to blood flow measurements in the microcirculation field, Hitt et al used the gradient-based optical flow algorithm to measure the blood flow in the venular network in the hamster cremaster muscle.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, particle image velocimetry (PIV) has become a powerful tool for quantitative measurement of flow velocities in bioengineering field, such as flows around the artificial heart and valve (30) - (32) . As an application to blood flow measurements in the microcirculation field, Hitt et al used the gradient-based optical flow algorithm to measure the blood flow in the venular network in the hamster cremaster muscle.…”
Section: Discussionmentioning
confidence: 99%
“…Flow fluctuations caused by beat-to-beat variability were minimized by averaging valid velocities in each IR for a minimum of 50 image pairs. The resulting velocities for each image pair were applied to the fluid centroid of the IRs and were then factored into a first-order wall shear rate algorithm, previously described by Hochareon et al [19]. The accuracy of the wall shear rate calculation is dependent upon the error of both the measured IR velocity and its orthogonal distance to the device wall.…”
Section: Methodsmentioning
confidence: 99%
“…7). 17,26,[45][46][47]64,66,68,76,77,88,91,97,98,103,130,138 However, PIV methods were mainly two dimensional until Bru¨cker introduced Stereo-PIV based on the use of two digital cameras and PIV algorithms to study the flow past artificial heart valves. 21 The testing requirements for performing stereo-PIV for characterizing the flow through mechanical heart valves has been well described by Morbiducci et al 115 Another breakthrough in PIV was the development of defocusing digital particle image velocimetry (D-DPIV).…”
Section: Particle Image Velocimetry Of Heart Valvesmentioning
confidence: 99%