Water-based condensation particle counters comparison near a major freeway with significant heavy-duty diesel traffic

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…This was also pointed out by the work of Bau et al (2019) which highlighted that the accuracy of w-CPC is dependent on their technical design. To minimize instrumental or model differences, post-data correction equations were proposed by Lee et al (2013) to adjust the data from TSI water-based CPC using exponential models. Bau et al (2017Bau et al ( , 2019 show that w&b-CPC studied were found to be within ± 25 % of the reference, except for a w-CPC (TSI model 3787) known to be highly sensitive to particle hydrophobicity.…”
Section: Experimental Setup and Smps Typesmentioning
confidence: 99%
“…This was also pointed out by the work of Bau et al (2019) which highlighted that the accuracy of w-CPC is dependent on their technical design. To minimize instrumental or model differences, post-data correction equations were proposed by Lee et al (2013) to adjust the data from TSI water-based CPC using exponential models. Bau et al (2017Bau et al ( , 2019 show that w&b-CPC studied were found to be within ± 25 % of the reference, except for a w-CPC (TSI model 3787) known to be highly sensitive to particle hydrophobicity.…”
Section: Experimental Setup and Smps Typesmentioning
confidence: 99%
“…The numeric modeling approach used here has been documented in previous publications (Hering et al, 2014;Lewis and Hering, 2013). First, the temperature and humidity profiles were computed using the finite element modeling software -COMSOL Multiphysics®.…”
Section: Numerical Simulation 135mentioning
confidence: 99%
“…tube extending through a 154 mm conditioner, a 76 mm initiator, and a 100 mm moderator, with a design flow rate of 1.5 L/min. Next, the particle growth, temperature and humidity profiles were calculated using a numerical model developed by Lewis and Hering (Lewis and Hering, 2013), written in Igor Pro 140 (Wavementrics, Beaverton, OR). Their simulation results suggest that the three-stage configuration is superior in decreasing the amount of water vapor and lowering the particle loss and variation in detection and collection, avoiding the side-effect of heating the flow.…”
Section: Numerical Simulation 135mentioning
confidence: 99%
See 2 more Smart Citations