Water extraction of plant tissues for analysis by ion chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2003
2003
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 7 publications
0
8
0
Order By: Relevance
“…Analysis was with methods provided by the manufacturer (TKN: QuikChem method 13-107-06-2-D; TKP: QuikChem method 13-115-01-1-B). To determine levels of ions, tissues were extracted according to the methods of Russo and Karmakar (1998). Levels of calcium, potassium, magnesium, sodium, nitrate-N, nitrite-N, phosphate (PO 4 ), and sulfate (SO 4 ) were determined following methods provided by the manufacturer (anions: Quik-Chem method 10-510-00-1-A; cations: Quik-Chem method 10-520-00-1-B).…”
Section: Methodsmentioning
confidence: 99%
“…Analysis was with methods provided by the manufacturer (TKN: QuikChem method 13-107-06-2-D; TKP: QuikChem method 13-115-01-1-B). To determine levels of ions, tissues were extracted according to the methods of Russo and Karmakar (1998). Levels of calcium, potassium, magnesium, sodium, nitrate-N, nitrite-N, phosphate (PO 4 ), and sulfate (SO 4 ) were determined following methods provided by the manufacturer (anions: Quik-Chem method 10-510-00-1-A; cations: Quik-Chem method 10-520-00-1-B).…”
Section: Methodsmentioning
confidence: 99%
“…Sulphur was analyzed using a Leco SÁ144DR S Combustion Analyzer (Leco Corporation, 3000, Lave view Ave, St. Joseph, MI) with the use of tungsten oxide as a combustion aid by the Cumberland Valley Analytical Services (CVAS, Hagerstown, MD). Serum sulphate was analyzed with high performance ion chromatography according to Russo et al (1998) at the Veterinary Diagnostic Laboratory of Colorado State University (Fort Collins, CO). Water sulphate was determined using inductively coupled plasma atomic emission spectroscopy (ICP-AES) according to the standard methods for the examination of water and waste water by the Saskatchewan Research Council Analytical Laboratory (Anonymous 2005).…”
Section: Chemical Analysismentioning
confidence: 99%
“…Inorganic and organic anions were extracted with water according to Russo and Karmarkar (1998) and analyzed by ion chromatography with conductivity detection (IC-CD) using a DX-500 liquid chromatograph (Dionex). Inorganic anions were separated on an IonPac AS12A column (Dionex), whereas both inorganic and organic anions were separated on a microbore IonPac AS11-HC column (Dionex).…”
Section: Inorganic and Organic Anionsmentioning